CAT#:
86-105
Eppendorf
Eppendorf Research Plus® Pipettors
Variable Volume, 10-100µl, 1 Pipettor/Unit
Variable Volume, 50 - 1200ul, 1 Pipettor/Unit
Variable Volume, 0.1-2.5µl, 1 Pipettor/Unit
Variable Volume, 1 - 20µl, 1 Pipettor/Unit
Variable Volumes, 120-1200µl, 1 Pipettor/Unit
For Use With 10ml Tips, 1 Pipettor/Unit
Variable Volume, 5 - 100µl, 1 Pipettor/Unit
Variable Volume, 1 - 20µl, 1 Pipettor/Unit
Variable Volume, 0.5-10µl, 1 Pipettor/Unit
Variable Volume, 5 - 100µl, 1 Pipettor/Unit
Variable Volumes, 30-300µl, 1 Pipettor/Unit
For Use With 200µl Tips, 1 Pipettor/Unit
For Use With 200µl Tips, 1 Pipettor/Unit
Variable Volume, 0.5-10µl, 1 Pipettor/Unit
Includes epT.I.P.S. Sample Bag, 1 Pipettor/Unit
For Use With 200µl Tips, 1 Pipettor/Unit
For Use With 1000µl Tips, 1 Pipettor/Unit
For Use With 5ml Tips, 1 Pipettor/Unit
For Use w/10µl XL Tips, 1 Pipettor/Unit
Variable Volume, 0.5-10µl, 1 Pipettor/Unit
For Use With 300µl Tips, 1 Pipettor/Unit
Variable Volume, 10-100µl, 1 Pipettor/Unit
Variable Volume, 30-300µl, 1 Pipettor/Unit
23 product variations: View Options
Product Overview
- For use with 200µl tips
- Control button: very low operating force, color indicates pipette volume, positioned for perfect ergonomics
- Ejector: very low operating force, positioned for perfect ergonomics
- Secondary adjustment to adjust pipette to a liquid very different than water
- Eppendorf PerfectPiston™: ultra light piston made of Fortron® (not in 2.5 µL, 10 µL, 5 mL and 10 mL pipettes)
- Quick connection clip
- Spring loaded tip cone: improved ergonomics, tight fit to the tip (not in 5 mL and 10 mL pipettes)
- Ultra lightweight
Product Overview
- For use with 1000ul tips
- Control button: very low operating force, color indicates pipette volume, positioned for perfect ergonomics
- Ejector: very low operating force, positioned for perfect ergonomics
- Secondary adjustment to adjust pipette to a liquid very different than water
- Eppendorf PerfectPiston™: ultra light piston made of Fortron® (not in 2.5 µL, 10 µL, 5 mL and 10 mL pipettes)
- Quick connection clip
- Spring loaded tip cone: improved ergonomics, tight fit to the tip (not in 5 mL and 10 mL pipettes)
- Ultra lightweight
Product Overview
- For use with 10µl tips
- Control button: very low operating force, color indicates pipette volume, positioned for perfect ergonomics
- Ejector: very low operating force, positioned for perfect ergonomics
- Secondary adjustment to adjust pipette to a liquid very different than water
- Eppendorf PerfectPiston™: ultra light piston made of Fortron® (not in 2.5 µL, 10 µL, 5 mL and 10 mL pipettes)
- Quick connection clip
- Spring loaded tip cone: improved ergonomics, tight fit to the tip (not in 5 mL and 10 mL pipettes)
- Ultra lightweight
Product Overview
- Includes Research Plus 16-channel pipettor and box of epT.I.P.S.
- For use with 20ul tips
- Control button: very low operating force, color indicates pipette volume, positioned for perfect ergonomics
- Ejector: very low operating force, positioned for perfect ergonomics
- Secondary adjustment to adjust pipette to a liquid very different than water
- Eppendorf PerfectPiston™: ultra light piston made of Fortron®
- Spring loaded tip cone: improved ergonomics, tight fit to the tip
- 3 year warranty
Product Overview
- For use with 1000µl tips
- Control button: very low operating force, color indicates pipette volume, positioned for perfect ergonomics
- Ejector: very low operating force, positioned for perfect ergonomics
- Secondary adjustment to adjust pipette to a liquid very different than water
- Eppendorf PerfectPiston™: ultra light piston made of Fortron® (not in 2.5 µL, 10 µL, 5 mL and 10 mL pipettes)
- Quick connection clip
- Spring loaded tip cone: improved ergonomics, tight fit to the tip (not in 5 mL and 10 mL pipettes)
- Ultra lightweight
Product Overview
- Only a few turns to reach your desired volume
- Control button: very low operating force, color indicates pipette volume, positioned for perfect ergonomics
- Ejector: very low operating force, positioned for perfect ergonomics
- Secondary adjustment to adjust pipette to a liquid very different than water
- Eppendorf PerfectPiston™: ultra light piston made of Fortron® (not in 2.5 µL, 10 µL, 5 mL and 10 mL pipettes)
- Quick connection clip
- Spring loaded tip cone: improved ergonomics, tight fit to the tip (not in 5 mL and 10 mL pipettes)
- Ultra lightweight
Product Overview
- Includes Research Plus 24-channel pipettor and box of epT.I.P.S.
- For use with 20ul tips
- Control button: very low operating force, color indicates pipette volume, positioned for perfect ergonomics
- Ejector: very low operating force, positioned for perfect ergonomics
- Secondary adjustment to adjust pipette to a liquid very different than water
- Eppendorf PerfectPiston™: ultra light piston made of Fortron®
- Spring loaded tip cone: improved ergonomics, tight fit to the tip
- 3 year warranty
Product Overview
- Includes Research Plus 24-channel pipettor and box of epT.I.P.S.
- For use with 20ul tips
- Control button: very low operating force, color indicates pipette volume, positioned for perfect ergonomics
- Ejector: very low operating force, positioned for perfect ergonomics
- Secondary adjustment to adjust pipette to a liquid very different than water
- Eppendorf PerfectPiston™: ultra light piston made of Fortron®
- Spring loaded tip cone: improved ergonomics, tight fit to the tip
- 3 year warranty
Product Overview
- For use with 10µl Tips
- Control button: very low operating force, color indicates pipette volume, positioned for perfect ergonomics
- Ejector: very low operating force, positioned for perfect ergonomics
- Secondary adjustment to adjust pipette to a liquid very different than water
- Eppendorf PerfectPiston™: ultra light piston made of Fortron® (not in 2.5 µL, 10 µL, 5 mL and 10 mL pipettes)
- Quick connection clip
- Spring loaded tip cone: improved ergonomics, tight fit to the tip (not in 5 mL and 10 mL pipettes)
- Ultra lightweight
Product Overview
- Includes Research Plus 16-channel pipettor and box of epT.I.P.S.
- For use with 20ul tips
- Control button: very low operating force, color indicates pipette volume, positioned for perfect ergonomics
- Ejector: very low operating force, positioned for perfect ergonomics
- Secondary adjustment to adjust pipette to a liquid very different than water
- Eppendorf PerfectPiston™: ultra light piston made of Fortron®
- Spring loaded tip cone: improved ergonomics, tight fit to the tip
- 3 year warranty
Product Overview
- For use with 300µl tips
- Control button: very low operating force, color indicates pipette volume, positioned for perfect ergonomics
- Ejector: very low operating force, positioned for perfect ergonomics
- Secondary adjustment to adjust pipette to a liquid very different than water
- Eppendorf PerfectPiston™: ultra light piston made of Fortron® (not in 2.5 µL, 10 µL, 5 mL and 10 mL pipettes)
- Quick connection clip
- Spring loaded tip cone: improved ergonomics, tight fit to the tip (not in 5 mL and 10 mL pipettes)
- Ultra lightweight
Product Overview
- Only a few turns to reach your desired volume
- Control button: very low operating force, color indicates pipette volume, positioned for perfect ergonomics
- Ejector: very low operating force, positioned for perfect ergonomics
- Secondary adjustment to adjust pipette to a liquid very different than water
- Eppendorf PerfectPiston™: ultra light piston made of Fortron® (not in 2.5 µL, 10 µL, 5 mL and 10 mL pipettes)
- Quick connection clip
- Spring loaded tip cone: improved ergonomics, tight fit to the tip (not in 5 mL and 10 mL pipettes)
- Ultra lightweight
Product Overview
- Only a few turns to reach your desired volume
- Control button: very low operating force, color indicates pipette volume, positioned for perfect ergonomics
- Ejector: very low operating force, positioned for perfect ergonomics
- Secondary adjustment to adjust pipette to a liquid very different than water
- Eppendorf PerfectPiston™: ultra light piston made of Fortron® (not in 2.5 µL, 10 µL, 5 mL and 10 mL pipettes)
- Quick connection clip
- Spring loaded tip cone: improved ergonomics, tight fit to the tip (not in 5 mL and 10 mL pipettes)
- Ultra lightweight
Product Overview
- For use with 20ul tips
- Control button: very low operating force, color indicates pipette volume, positioned for perfect ergonomics
- Ejector: very low operating force, positioned for perfect ergonomics
- Secondary adjustment to adjust pipette to a liquid very different than water
- Eppendorf PerfectPiston™: ultra light piston made of Fortron® (not in 2.5 µL, 10 µL, 5 mL and 10 mL pipettes)
- Quick connection clip
- Spring loaded tip cone: improved ergonomics, tight fit to the tip (not in 5 mL and 10 mL pipettes)
- Ultra lightweight
Product Overview
- For use with Eppendorf 10ul tips
- Control button: very low operating force, color indicates pipette volume, positioned for perfect ergonomics
- Ejector: very low operating force, positioned for perfect ergonomics
- Secondary adjustment to adjust pipette to a liquid very different than water
- Eppendorf PerfectPiston™: ultra light piston made of Fortron® (not in 2.5 µL, 10 µL, 5 mL and 10 mL pipettes)
- Quick connection clip
- Spring loaded tip cone: improved ergonomics, tight fit to the tip (not in 5 mL and 10 mL pipettes)
- Ultra lightweight
Product Overview
- Only a few turns to reach your desired volume
- Control button: very low operating force, color indicates pipette volume, positioned for perfect ergonomics
- Ejector: very low operating force, positioned for perfect ergonomics
- Secondary adjustment to adjust pipette to a liquid very different than water
- Eppendorf PerfectPiston™: ultra light piston made of Fortron® (not in 2.5 µL, 10 µL, 5 mL and 10 mL pipettes)
- Quick connection clip
- Spring loaded tip cone: improved ergonomics, tight fit to the tip (not in 5 mL and 10 mL pipettes)
- Ultra lightweight
Product Overview
- Only a few turns to reach your desired volume
- Control button: very low operating force, color indicates pipette volume, positioned for perfect ergonomics
- Ejector: very low operating force, positioned for perfect ergonomics
- Secondary adjustment to adjust pipette to a liquid very different than water
- Eppendorf PerfectPiston™: ultra light piston made of Fortron® (not in 2.5 µL, 10 µL, 5 mL and 10 mL pipettes)
- Quick connection clip
- Spring loaded tip cone: improved ergonomics, tight fit to the tip (not in 5 mL and 10 mL pipettes)
- Ultra lightweight
Product Overview
- Only a few turns to reach your desired volume
- Control button: very low operating force, color indicates pipette volume, positioned for perfect ergonomics
- Ejector: very low operating force, positioned for perfect ergonomics
- Secondary adjustment to adjust pipette to a liquid very different than water
- Eppendorf PerfectPiston™: ultra light piston made of Fortron® (not in 2.5 µL, 10 µL, 5 mL and 10 mL pipettes)
- Quick connection clip
- Spring loaded tip cone: improved ergonomics, tight fit to the tip (not in 5 mL and 10 mL pipettes)
- Ultra lightweight
Product Overview
- For use with 10XL Tips, cat# 23-121R and 23-401
- Control button: very low operating force, color indicates pipette volume, positioned for perfect ergonomics
- Ejector: very low operating force, positioned for perfect ergonomics
- Secondary adjustment to adjust pipette to a liquid very different than water
- Eppendorf PerfectPiston™: ultra light piston made of Fortron® (not in 2.5 µL, 10 µL, 5 mL and 10 mL pipettes)
- Quick connection clip
- Spring loaded tip cone: improved ergonomics, tight fit to the tip (not in 5 mL and 10 mL pipettes)
- Ultra lightweight
Product Overview
- For use with 20µl tips
- Control button: very low operating force, color indicates pipette volume, positioned for perfect ergonomics
- Ejector: very low operating force, positioned for perfect ergonomics
- Secondary adjustment to adjust pipette to a liquid very different than water
- Eppendorf PerfectPiston™: ultra light piston made of Fortron® (not in 2.5 µL, 10 µL, 5 mL and 10 mL pipettes)
- Quick connection clip
- Spring loaded tip cone: improved ergonomics, tight fit to the tip (not in 5 mL and 10 mL pipettes)
- Ultra lightweight
Product Overview
- Only a few turns to reach your desired volume
- Control button: very low operating force, color indicates pipette volume, positioned for perfect ergonomics
- Ejector: very low operating force, positioned for perfect ergonomics
- Secondary adjustment to adjust pipette to a liquid very different than water
- Eppendorf PerfectPiston™: ultra light piston made of Fortron® (not in 2.5 µL, 10 µL, 5 mL and 10 mL pipettes)
- Quick connection clip
- Spring loaded tip cone: improved ergonomics, tight fit to the tip (not in 5 mL and 10 mL pipettes)
- Ultra lightweight
Product Overview
- For use with 200µl tips
- Control button: very low operating force, color indicates pipette volume, positioned for perfect ergonomics
- Ejector: very low operating force, positioned for perfect ergonomics
- Secondary adjustment to adjust pipette to a liquid very different than water
- Eppendorf PerfectPiston™: ultra light piston made of Fortron® (not in 2.5 µL, 10 µL, 5 mL and 10 mL pipettes)
- Quick connection clip
- Spring loaded tip cone: improved ergonomics, tight fit to the tip (not in 5 mL and 10 mL pipettes)
- Ultra lightweight
Product Overview
- For use with 300ul tips
- Control button: very low operating force, color indicates pipette volume, positioned for perfect ergonomics
- Ejector: very low operating force, positioned for perfect ergonomics
- Secondary adjustment to adjust pipette to a liquid very different than water
- Eppendorf PerfectPiston™: ultra light piston made of Fortron® (not in 2.5 µL, 10 µL, 5 mL and 10 mL pipettes)
- Quick connection clip
- Spring loaded tip cone: improved ergonomics, tight fit to the tip (not in 5 mL and 10 mL pipettes)
- Ultra lightweight
Technical Specifications
Product Type | Pipettes |
Pipetting Type | Air-cushion system |
Number Of Channels | 12-channel |
Volume Range | 10 – 100 μL |
Color Code | yellow |
Volume Increment | 0.1 μL |
Operating Mode | mechanical |
Spring-loaded Tip Cone | yes |
Random Measurement Error | 5 μL: ± 4%; ± 0.2 μL10 μL: ± 2%; ± 0.2 μL50 μL: ± 0.8%; ± 0.4 μL100 μL: ± 0.3%; ± 0.3 μL |
Systematic Measurement Error | 5 μL: ± 6%; ± 0.03 μL10 μL: ± 3%; ± 0.3 μL50 μL: ± 1%; ± 0.5 μL100 μL: ± 0.8%; ± 0.8 μL |
Autoclavable | yes |
Consumables | epT.I.P.S.® |
Open System (third Party Consumables) | yes |
Delivery Content | Pipette, epT.I.P.S.® Box 2.0 pipette tips, Operating manual, Certificate, Adjustment tool (Allen key with blue handle), Adjustment seal for temporary adjustment (x5), Grease for pipettes, Locking clip (to prevent spring action) (x3), O-ring tool |
Technical Specifications
Product Type | Pipettes |
Pipetting Type | Air-cushion system |
Number Of Channels | 12-channel |
Volume Range | 120 – 1,200 μL |
Color Code | dark green |
Volume Increment | 1 μL |
Operating Mode | mechanical |
Spring-loaded Tip Cone | no |
Random Measurement Error | 50 μL: ± 1.2%; ± 0.6 μL120.0 μL: ± 0.9%; ± 1.08 μL600 μL: ± 0.4%; ± 2.4 μL1200 μL: ± 3.6%; ± 3.6 μL |
Systematic Measurement Error | 50 μL: ± 8%; ± 4 μL120.0 μL: ± 6%; ± 7.2 μL600 μL: ± 2.7%; ± 16.2 μL1200 μL: ± 1.2%; ± 14.4 μL |
Autoclavable | yes |
Consumables | epT.I.P.S.® |
Open System (third Party Consumables) | yes |
Delivery Content | Pipette, Operating manual, Certificate, Adjustment tool (Allen key with blue handle), Adjustment seal for temporary adjustment (x5), Grease for pipettes, Unlocking tool, O-ring tool |
Technical Specifications
Product Type | Pipettes |
Pipetting Type | Air-cushion system |
Number Of Channels | 1-channel |
Volume Range | 0.1 – 2.5 µL |
Color Code | dark gray |
Volume Increment | 0.002 µL |
Operating Mode | mechanical |
Spring-loaded Tip Cone | yes |
Random Measurement Error | 0.10 µL: ± 12%; ± 0.012 µL0.25 µL: ± 6%; ± 0.015 µL1.25 µL: ± 1.5%; ± 0.01875 µL2.5 µL: ± 0.7%; ± 0.0175 µL |
Systematic Measurement Error | 0.10 µL: ± 48%; ± 0.048 µL0.25 µL: ± 12%; ± 0.03 µL1.25 µL: ± 2.5%; ± 0.031 µL2.5 µL: ± 1.4%; ± 0.035 µL |
Autoclavable | yes |
Consumables | epT.I.P.S.® |
Open System (third Party Consumables) | yes |
Delivery Content | Pipette, epT.I.P.S.® Box 2.0 pipette tips, Operating manual, Certificate, Adjustment tool (Allen key with blue handle), Adjustment seal for temporary adjustment (x5), Grease for pipettes, Locking ring (to prevent spring action) |
Technical Specifications
Product Type | Pipettes |
Pipetting Type | Air-cushion system |
Number Of Channels | 16-channel |
Volume Range | 1 – 20 μL |
Color Code | light pink |
Volume Increment | 0.02 μL |
Operating Mode | mechanical |
Spring-loaded Tip Cone | yes |
Random Measurement Error | 1 μL: ± 8%; ± 0.08 μL2 μL: ± 5%; ± 0.1 μL10 μL: ± 2%; ± 0.2 μL20 μL: ± 1%; ± 0.2 μL |
Systematic Measurement Error | 1 μL: ± 12%; ± 0.12 μL2 μL: ± 8%; ± 0.16 μL10 μL: ± 4%; ± 0.2 μL20 μL: ± 2%; ± 0.4 μL |
Autoclavable | yes |
Consumables | only epT.I.P.S. 384 |
Open System (third Party Consumables) | yes |
Delivery Content | Pipette, epT.I.P.S.® Box 2.0 pipette tips, Operating manual, Certificate, Adjustment tool (Allen key with blue handle), Adjustment seal for temporary adjustment (x5), Grease for pipettes |
Technical Specifications
Product Type | Pipettes |
Pipetting Type | Air-cushion system |
Number Of Channels | 8-channel |
Volume Range | 120 – 1,200 μL |
Color Code | dark green |
Volume Increment | 1 μL |
Operating Mode | mechanical |
Spring-loaded Tip Cone | no |
Random Measurement Error | 50 μL: ± 1.2%; ± 0.6 μL120.0 μL: ± 0.9%; ± 1.08 μL600 μL: ± 0.4%; ± 2.4 μL1200 μL: ± 0.3%; ± 3.6 μL |
Systematic Measurement Error | 50 μL: ± 8%; ± 4 μL120.0 μL: ± 6%; ± 7.2 μL600 μL: ± 2.7%; ± 16.2 μL1200 μL: ± 1.2%; ± 14.4 μL |
Autoclavable | yes |
Consumables | epT.I.P.S.® |
Open System (third Party Consumables) | yes |
Delivery Content | Pipette, Operating manual, Certificate, Adjustment tool (Allen key with blue handle), Adjustment seal for temporary adjustment (x5), Grease for pipettes, Unlocking tool, O-ring tool |
Technical Specifications
Product Type | Pipettes |
Pipetting Type | Air-cushion system |
Number Of Channels | 1-channel |
Volume Range | 1 – 10 mL |
Color Code | turquoise |
Volume Increment | 0.01 mL |
Operating Mode | mechanical |
Spring-loaded Tip Cone | no |
Random Measurement Error | 500 μL: ± 1.2%; ± 6 μL1000 μL: ± 0.6%; ± 6 μL5000 μL: ± 0.2%; ± 10 μL10000 μL: ± 0.15%; ± 15 μL |
Systematic Measurement Error | 500 μL: ± 6%; ± 30 μL1000 μL: ± 1%; ± 30 μL5000 μL: ± 0.8%; ± 40 μL10000 μL: ± 0.6%; ± 60 μL |
Autoclavable | yes |
Consumables | epT.I.P.S.® |
Open System (third Party Consumables) | yes |
Delivery Content | Pipette, epT.I.P.S.® pipette tips sample bag, Operating manual, Certificate, Adjustment tool (Allen key with blue handle), Adjustment seal for temporary adjustment (x5), Grease for pipettes, Protection filter (x10), Pipette wrench |
Technical Specifications
Product Type | Pipettes |
Pipetting Type | Air-cushion system |
Number Of Channels | 24-channel |
Volume Range | 5 – 100 μL |
Color Code | light yellow |
Volume Increment | 0.1 μL |
Operating Mode | mechanical |
Spring-loaded Tip Cone | yes |
Random Measurement Error | 5 μL: ± 4%; ± 0.2 μL10 μL: ± 2%; ± 0.2 μL50 μL: ± 0.8%; ± 0.4 μL100 μL: ± 0.6%; ± 0.6 μL |
Systematic Measurement Error | 5 μL: ± 6%; ± 0.3 μL10 μL: ± 3%; ± 0.3 μL50 μL: ± 1.2%; ± 0.6 μL100 μL: ± 1%; ± 1 μL |
Autoclavable | yes |
Consumables | only epT.I.P.S. 384 |
Open System (third Party Consumables) | yes |
Delivery Content | Pipette, epT.I.P.S.® Box 2.0 pipette tips, Operating manual, Certificate, Adjustment tool (Allen key with blue handle), Adjustment seal for temporary adjustment (x5), Grease for pipettes |
Technical Specifications
Product Type | Pipettes |
Pipetting Type | Air-cushion system |
Number Of Channels | 24-channel |
Volume Range | 1 – 20 μL |
Color Code | light pink |
Volume Increment | 0.02 μL |
Operating Mode | mechanical |
Spring-loaded Tip Cone | yes |
Random Measurement Error | 1 μL: ± 8%; ± 0.08 μL2 μL: ± 5%; ± 0.1 μL10 μL: ± 2%; ± 0.2 μL20 μL: ± 1%; ± 0.2 μL |
Systematic Measurement Error | 1 μL: ± 12%; ± 0.12 μL2 μL: ± 8%; ± 0.16 μL10 μL: ± 4%; ± 0.2 μL20 μL: ± 2%; ± 0.4 μL |
Autoclavable | yes |
Consumables | only epT.I.P.S. 384 |
Open System (third Party Consumables) | yes |
Delivery Content | Pipette, epT.I.P.S.® Box 2.0 pipette tips, Operating manual, Certificate, Adjustment tool (Allen key with blue handle), Adjustment seal for temporary adjustment (x5), Grease for pipettes |
Technical Specifications
Product Type | Pipettes |
Pipetting Type | Air-cushion system |
Number Of Channels | 1-channel |
Volume Range | 0.5 – 10 μL |
Color Code | medium gray |
Volume Increment | 0.01 μL |
Operating Mode | mechanical |
Spring-loaded Tip Cone | yes |
Random Measurement Error | 0.5 μL: ± 5%; ± 0.025 μL1 μL: ± 1.8%; ± 0.018 μL5 μL: ± 0.8%; ± 0.04 μL10 μL: ± 0.4%; ± 0.04 μL |
Systematic Measurement Error | 0.5 μL: ± 8%; ± 0.04 μL1 μL: ± 2.5%; ± 0.025 μL5 μL: ± 1.5%; ± 0.075 μL10 μL: ± 1%; ± 0.1 μL |
Autoclavable | yes |
Consumables | epT.I.P.S.® |
Open System (third Party Consumables) | yes |
Delivery Content | Pipette, epT.I.P.S.® Box 2.0 pipette tips, Operating manual, Certificate, Adjustment tool (Allen key with blue handle), Adjustment seal for temporary adjustment (x5), Grease for pipettes, Locking ring (to prevent spring action) |
Technical Specifications
Product Type | Pipettes |
Pipetting Type | Air-cushion system |
Number Of Channels | 16-channel |
Volume Range | 5 – 100 μL |
Color Code | light yellow |
Volume Increment | 0.1 μL |
Operating Mode | mechanical |
Spring-loaded Tip Cone | yes |
Random Measurement Error | 5 μL: ± 4%; ± 0.2 μL10 μL: ± 2%; ± 0.2 μL50 μL: ± 0.8%; ± 0.4 μL100 μL: ± 0.6%; ± 0.6 μL |
Systematic Measurement Error | 5 μL: ± 6%; ± 0.3 μL10 μL: ± 3%; ± 0.3 μL50 μL: ± 1.2%; ± 0.6 μL100 μL: ± 1%; ± 1 μL |
Autoclavable | yes |
Consumables | only epT.I.P.S. 384 |
Open System (third Party Consumables) | yes |
Delivery Content | Pipette, epT.I.P.S.® Box 2.0 pipette tips, Operating manual, Certificate, Adjustment tool (Allen key with blue handle), Adjustment seal for temporary adjustment (x5), Grease for pipettes |
Technical Specifications
Product Type | Pipettes |
Pipetting Type | Air-cushion system |
Number Of Channels | 8-channel |
Volume Range | 30 – 300 μL |
Color Code | orange |
Volume Increment | 0.1 μL |
Operating Mode | mechanical |
Spring-loaded Tip Cone | yes |
Random Measurement Error | 15 μL: ± 2%; ± 0.3 μL30 μL: ± 1%; ± 0.3 μL150 μL: ± 0.5%; ± 0.75 μL300 μL: ± 0.3%; ± 0.9 μL |
Systematic Measurement Error | 15 μL: ± 6%; ± 0.09 μL30 μL: ± 3%; ± 0.9 μL150 μL: ± 1%; ± 1.5 μL300 μL: ± 0.6%; ± 1.8 μL |
Autoclavable | yes |
Consumables | epT.I.P.S.® |
Open System (third Party Consumables) | yes |
Delivery Content | Pipette, epT.I.P.S.® Box 2.0 pipette tips, Operating manual, Certificate, Adjustment tool (Allen key with blue handle), Adjustment seal for temporary adjustment (x5), Grease for pipettes, Locking clip (to prevent spring action) (x2), O-ring tool |
Technical Specifications
Product Type | Pipettes |
Pipetting Type | Air-cushion system |
Number Of Channels | 1-channel |
Volume Range | 20 – 200 μL |
Color Code | yellow |
Volume Increment | 0.2 μL |
Operating Mode | mechanical |
Spring-loaded Tip Cone | yes |
Random Measurement Error | 10 μL: ± 1.4%; ± 0.14 μL20 μL: ± 0.7%; ± 0.14 μL100 μL: ± 0.3%; ± 0.3 μL200 μL: ± 0.2%; ± 0.4 μL |
Systematic Measurement Error | 10 μL: ± 5%; ± 0.5 μL20 μL: ± 2.5%; ± 0.5 μL100 μL: ± 1%; ± 1 μL200 μL: ± 0.6%; ± 1.2 μL |
Autoclavable | yes |
Consumables | epT.I.P.S.® |
Open System (third Party Consumables) | yes |
Delivery Content | Pipette, epT.I.P.S.® Box 2.0 pipette tips, Operating manual, Certificate, Adjustment tool (Allen key with blue handle), Adjustment seal for temporary adjustment (x5), Grease for pipettes, Locking ring (to prevent spring action) |
Technical Specifications
Product Type | Pipettes |
Pipetting Type | Air-cushion system |
Number Of Channels | 1-channel |
Volume Range | 2 – 20 μL |
Color Code | yellow |
Volume Increment | 0.02 μL |
Operating Mode | mechanical |
Spring-loaded Tip Cone | yes |
Random Measurement Error | 1 μL: ± 3%; ± 0.03 μL2 μL: ± 1.5%; ± 0.3 μL10 μL: ± 0.6%; ± 0.06 μL20 μL: ± 0.3%; ± 0.06 μL |
Systematic Measurement Error | 1 μL: ± 10%; ± 0.1 μL2 μL: ± 5%; ± 0.1 μL10 μL: ± 1.2%; ± 0.12 μL20 μL: ± 1%; ± 0.2 μL |
Autoclavable | yes |
Consumables | epT.I.P.S.® |
Open System (third Party Consumables) | yes |
Delivery Content | Pipette, epT.I.P.S.® Box 2.0 pipette tips, Operating manual, Certificate, Adjustment tool (Allen key with blue handle), Adjustment seal for temporary adjustment (x5), Grease for pipettes, Locking ring (to prevent spring action) |
Technical Specifications
Product Type | Pipettes |
Pipetting Type | Air-cushion system |
Number Of Channels | 12-channel |
Volume Range | 0.5 – 10 μL |
Color Code | medium gray |
Volume Increment | 0.01 μL |
Operating Mode | mechanical |
Spring-loaded Tip Cone | yes |
Random Measurement Error | 0.5 μL: ± 8%; ± 0.04 μL1 μL: ± 5%; ± 0.05 μL5 μL: ± 2%; ± 0.1 μL10 μL: ± 1%; ± 0.1 μL |
Systematic Measurement Error | 0.5 μL: ± 12%; ± 0.06 μL1 μL: ± 8%; ± 0.08 μL5 μL: ± 4%; ± 0.2 μL10 μL: ± 2%; ± 0.2 μL |
Autoclavable | yes |
Consumables | epT.I.P.S.® |
Open System (third Party Consumables) | yes |
Delivery Content | Pipette, epT.I.P.S.® Box 2.0 pipette tips, Operating manual, Certificate, Adjustment tool (Allen key with blue handle), Adjustment seal for temporary adjustment (x5), Grease for pipettes, Locking clip (to prevent spring action) (x3), O-ring tool |
Technical Specifications
Product Type | Pipettes |
Pipetting Type | Air-cushion system |
Number Of Channels | 1-channel |
Volume Range | 0.25 – 2.5 mL |
Color Code | red |
Volume Increment | 0.002 mL |
Operating Mode | mechanical |
Spring-loaded Tip Cone | no |
Random Measurement Error | 125 μL: ± 1.4%; ± 1.75 μL250 μL: ± 1.2%; ± 3 μL1250 μL: ± 0.2%; ± 2.5 μL2500 μL: ± 0.2%; ± 5 μL |
Systematic Measurement Error | 125 μL: ± 5%; ± 6.25 μL250 μL: ± 4.8%; ± 12 μL1250 μL: ± 0.8%; ± 10 μL2500 μL: ± 0.6%; ± 15 μL |
Autoclavable | yes |
Consumables | epT.I.P.S.® |
Open System (third Party Consumables) | yes |
Delivery Content | Pipette, epT.I.P.S.® pipette tips sample bag, Operating manual, Certificate, Adjustment tool (Allen key with blue handle), Adjustment seal for temporary adjustment (x5), Grease for pipettes, Protection filter (x10), Pipette wrench |
Technical Specifications
Product Type | Pipettes |
Pipetting Type | Air-cushion system |
Number Of Channels | 1-channel |
Volume Range | 10 – 100 μL |
Color Code | yellow |
Volume Increment | 0.1 μL |
Operating Mode | mechanical |
Spring-loaded Tip Cone | yes |
Random Measurement Error | 5 μL: ± 2%; ± 0.1 μL10 μL: ± 1%; ± 0.1 μL50 μL: ± 0.3%; ± 0.15 μL100 μL: ± 0.2%; ± 0.2 μL |
Systematic Measurement Error | 5 μL: ± 6%; ± 0.3 μL10 μL: ± 3%; ± 0.3 μL50 μL: ± 1%; ± 0.5 μL100 μL: ± 0.8%; ± 0.8 μL |
Autoclavable | yes |
Consumables | epT.I.P.S.® |
Open System (third Party Consumables) | yes |
Delivery Content | Pipette, epT.I.P.S.® Box 2.0 pipette tips, Operating manual, Certificate, Adjustment tool (Allen key with blue handle), Adjustment seal for temporary adjustment (x5), Grease for pipettes, Locking ring (to prevent spring action) |
Technical Specifications
Product Type | Pipettes |
Pipetting Type | Air-cushion system |
Number Of Channels | 1-channel |
Volume Range | 100 – 1,000 μL |
Color Code | blue |
Volume Increment | 1 μL |
Operating Mode | mechanical |
Spring-loaded Tip Cone | yes |
Random Measurement Error | 50 μL: ± 1.2%; ± 0.6 μL100 μL: ± 0.6%; ± 0.6 μL500 μL: ± 0.2%; ± 1 μL1000 μL: ± 0.2%; ± 2 μL |
Systematic Measurement Error | 50 μL: ± 6%; ± 3 μL100 μL: ± 3%; ± 3 μL500 μL: ± 1%; ± 5 μL1000 μL: ± 0.6%; ± 6 μL |
Autoclavable | yes |
Consumables | epT.I.P.S.® |
Open System (third Party Consumables) | yes |
Delivery Content | Pipette, epT.I.P.S.® Box 2.0 pipette tips, Operating manual, Certificate, Adjustment tool (Allen key with blue handle), Adjustment seal for temporary adjustment (x5), Grease for pipettes, Locking ring (to prevent spring action) |
Technical Specifications
Product Type | Pipettes |
Pipetting Type | Air-cushion system |
Number Of Channels | 1-channel |
Volume Range | 0.5 – 5 mL |
Color Code | violet |
Volume Increment | 0.005 mL |
Operating Mode | mechanical |
Spring-loaded Tip Cone | no |
Random Measurement Error | 250 μL: ± 1.2%; ± 3 μL500 μL: ± 0.6%; ± 3 μL2500 μL: ± 0.25%; ± 6.25 μL5000 μL: ± 0.15%; ± 7.5 μL |
Systematic Measurement Error | 250 μL: ± 4.8%; ± 12 μL500 μL: ± 2.4%; ± 12 μL2500 μL: ± 1.2%; ± 30 μL5000 μL: ± 0.6%; ± 30 μL |
Autoclavable | yes |
Consumables | epT.I.P.S.® |
Open System (third Party Consumables) | yes |
Delivery Content | Pipette, epT.I.P.S.® pipette tips sample bag, Operating manual, Certificate, Adjustment tool (Allen key with blue handle), Adjustment seal for temporary adjustment (x5), Grease for pipettes, Protection filter (x10), Pipette wrench |
Technical Specifications
Product Type | Pipettes |
Pipetting Type | Air-cushion system |
Number Of Channels | 1-channel |
Volume Range | 2 – 20 μL |
Color Code | light gray |
Volume Increment | 0.02 μL |
Operating Mode | mechanical |
Spring-loaded Tip Cone | yes |
Random Measurement Error | 1 μL: ± 3%; ± 0.03 μL2 μL: ± 1.5%; ± 0.03 μL10 μL: ± 0.6%; ± 0.06 μL20 μL: ± 0.3%; ± 0.06 μL |
Systematic Measurement Error | 1 μL: ± 10%; ± 0.1 μL2 μL: ± 5%; ± 0.1 μL10 μL: ± 1.2%; ± 0.12 μL20 μL: ± 1%; ± 0.2 μL |
Autoclavable | yes |
Consumables | epT.I.P.S.® |
Open System (third Party Consumables) | yes |
Delivery Content | Pipette, epT.I.P.S.® Box 2.0 pipette tips, Operating manual, Certificate, Adjustment tool (Allen key with blue handle), Adjustment seal for temporary adjustment (x5), Grease for pipettes, Locking ring (to prevent spring action) |
Technical Specifications
Product Type | Pipettes |
Pipetting Type | Air-cushion system |
Number Of Channels | 8-channel |
Volume Range | 0.5 – 10 μL |
Color Code | medium gray |
Volume Increment | 0.01 μL |
Operating Mode | mechanical |
Spring-loaded Tip Cone | yes |
Random Measurement Error | 0.5 μL: ± 8%; ± 0.04 μL1 μL: ± 5%; ± 0.05 μL5 μL: ± 2%; ± 0.1 μL10 μL: ± 1%; ± 0.1 μL |
Systematic Measurement Error | 0.5 μL: ± 12%; ± 0.06 μL1 μL: ± 8%; ± 0.08 μL5 μL: ± 4%; ± 0.2 μL10 μL: ± 2%; ± 0.2 μL |
Autoclavable | yes |
Consumables | epT.I.P.S.® |
Open System (third Party Consumables) | yes |
Delivery Content | Pipette, epT.I.P.S.® Box 2.0 pipette tips, Operating manual, Certificate, Adjustment tool (Allen key with blue handle), Adjustment seal for temporary adjustment (x5), Grease for pipettes, Locking clip (to prevent spring action) (x2), O-ring tool |
Technical Specifications
Product Type | Pipettes |
Pipetting Type | Air-cushion system |
Number Of Channels | 1-channel |
Volume Range | 30 – 300 μL |
Color Code | orange |
Volume Increment | 0.2 μL |
Operating Mode | mechanical |
Spring-loaded Tip Cone | yes |
Random Measurement Error | 15 μL: ± 1.4%; ± 0.21 μL30 μL: ± 0.7%; ± 0.21 μL150 μL: ± 0.3%; ± 0.45 μL300 μL: ± 0.2%; ± 0.6 μL |
Systematic Measurement Error | 15 μL: ± 5%; ± 0.75 μL30 μL: ± 2.5%; ± 0.75 μL150 μL: ± 1%; ± 1.5 μL300 μL: ± 0.6%; ± 1.8 μL |
Autoclavable | yes |
Consumables | epT.I.P.S.® |
Open System (third Party Consumables) | yes |
Delivery Content | Pipette, epT.I.P.S.® Box 2.0 pipette tips, Operating manual, Certificate, Adjustment tool (Allen key with blue handle), Adjustment seal for temporary adjustment (x5), Grease for pipettes, Locking ring (to prevent spring action) |
Technical Specifications
Product Type | Pipettes |
Pipetting Type | Air-cushion system |
Number Of Channels | 8-channel |
Volume Range | 10 – 100 μL |
Color Code | yellow |
Volume Increment | 0.1 μL |
Operating Mode | mechanical |
Spring-loaded Tip Cone | yes |
Random Measurement Error | 5 μL: ± 4%; ± 0.2 μL10 μL: ± 2%; ± 0.2 μL50 μL: ± 0.8%; ± 0.4 μL100 μL: ± 0.3%; ± 0.3 μL |
Systematic Measurement Error | 5 μL: ± 6%; ± 0.03 μL10 μL: ± 3%; ± 0.3 μL50 μL: ± 1%; ± 0.5 μL100 μL: ± 0.8%; ± 0.8 μL |
Autoclavable | yes |
Consumables | epT.I.P.S.® |
Open System (third Party Consumables) | yes |
Delivery Content | Pipette, epT.I.P.S.® Box 2.0 pipette tips, Operating manual, Certificate, Adjustment tool (Allen key with blue handle), Adjustment seal for temporary adjustment (x5), Grease for pipettes, Locking clip (to prevent spring action) (x2), O-ring tool |
Technical Specifications
Product Type | Pipettes |
Pipetting Type | Air-cushion system |
Number Of Channels | 12-channel |
Volume Range | 30 – 300 μL |
Color Code | orange |
Volume Increment | 0.1 μL |
Operating Mode | mechanical |
Spring-loaded Tip Cone | yes |
Random Measurement Error | 15 μL: ± 2%; ± 0.3 μL30 μL: ± 1%; ± 0.3 μL150 μL: ± 0.005%; ± 0.75 μL300 μL: ± 0.3%; ± 0.3 μL |
Systematic Measurement Error | 15 μL: ± 6%; ± 0.09 μL30 μL: ± 3%; ± 0.9 μL150 μL: ± 1%; ± 1.5 μL300 μL: ± 0.6%; ± 1.8 μL |
Autoclavable | yes |
Consumables | epT.I.P.S.® |
Open System (third Party Consumables) | yes |
Delivery Content | Pipette, epT.I.P.S.® Box 2.0 pipette tips, Operating manual, Certificate, Adjustment tool (Allen key with blue handle), Adjustment seal for temporary adjustment (x5), Grease for pipettes, Locking clip (to prevent spring action) (x3), O-ring tool |
Technical Documents
- 384. Ready. Set. Pipette!
- Calibration Done Right
- Get It Right! Selection Chart for Liquid Handling Instruments & Tips
- Increase Your Pipetting Productivity Today
- Natural Winners
- Pipette Service
- Pipette Service Done Right
- ACT - Research plus pipette, 0.1-2.5 μL (dark grey), single-channel, variable
- ACT - Research plus pipettes, single-channel, variable volume
- Grease for Pipettes
- Change Filter
- Chemical Resistance - Eppendorf Research® plus
- Combination of epT.I.P.S.® Pipette Tips with Eppendorf Pipettes
- Eppendorf Research® plus
- Eppendorf Research® plus - Factory Adjustment
- Eppendorf Research® plus - Temporary Adjustment
- Eppendorf Research® plus Spec Sheet
- Grease for Pipettes
- Locking Clips for Multi-Channel Lower Parts
- Pipette Service Form
- Standard operating procedure for manual dispensing systems
- 019 – Fundamentals of Dispensing
- 020 – Impact of Pipetting Techniques on Precision and Accuracy
- 021 – Influence of physical parameters on the dispensed volume of air-cushion pipette
- 024 – Cleaning and Inspection of Pipettes
- 025 – Calibration and Adjustment of Dispensing Systems in the Laboratory
- 035 – Five Challenges in Plate Assays that Can Be Mastered by the Right Choice of Pipetting Tool
- 046 – The Eppendorf PhysioCare Concept® - 3 Spheres Model
- 071 – How Can I Improve Sustainability in My Lab?
- 082 – What Really Matters
- 085 – Requirements and Eppendorf Solutions for Immunological Analyses
- 16- and 24-Channel Pipettes and epT.I.P.S.® 384
- 197 – The Eppendorf Research® plus Pipette - Lightweight, Reliable and Ergonomic
- 198 – The Eppendorf Mechanical Pipettes Research® plus and Reference® 2 – Fully Autoclavable, Easy Adjustment, Quick and Simple Maintenance
- 354 – The Tip of the Iceberg: How Pipette Tips Influence Results
- Accelerate 384-Well Pipetting
- Checklist for a More Sustainable Lab
- Maintenance of Eppendorf Research® plus pipettes
- Pipetting Techniques
- Transferring Non-Aqueous Liquids
Technical Documents
- 384. Ready. Set. Pipette!
- Calibration Done Right
- Get It Right! Selection Chart for Liquid Handling Instruments & Tips
- Increase Your Pipetting Productivity Today
- Natural Winners
- Pipette Service
- Pipette Service Done Right
- ACT - Research plus pipette, 1.0-10 mL (turquoise), single-channel, variable
- ACT - Research plus pipettes, single-channel, variable volume
- Grease for Pipettes
- Change Filter
- Chemical Resistance - Eppendorf Research® plus
- Combination of epT.I.P.S.® Pipette Tips with Eppendorf Pipettes
- Eppendorf Research® plus
- Eppendorf Research® plus - Factory Adjustment
- Eppendorf Research® plus - Temporary Adjustment
- Eppendorf Research® plus Spec Sheet
- Grease for Pipettes
- Locking Clips for Multi-Channel Lower Parts
- Pipette Service Form
- Standard operating procedure for manual dispensing systems
- 019 – Fundamentals of Dispensing
- 020 – Impact of Pipetting Techniques on Precision and Accuracy
- 021 – Influence of physical parameters on the dispensed volume of air-cushion pipette
- 024 – Cleaning and Inspection of Pipettes
- 025 – Calibration and Adjustment of Dispensing Systems in the Laboratory
- 035 – Five Challenges in Plate Assays that Can Be Mastered by the Right Choice of Pipetting Tool
- 046 – The Eppendorf PhysioCare Concept® - 3 Spheres Model
- 071 – How Can I Improve Sustainability in My Lab?
- 082 – What Really Matters
- 085 – Requirements and Eppendorf Solutions for Immunological Analyses
- 16- and 24-Channel Pipettes and epT.I.P.S.® 384
- 197 – The Eppendorf Research® plus Pipette - Lightweight, Reliable and Ergonomic
- 198 – The Eppendorf Mechanical Pipettes Research® plus and Reference® 2 – Fully Autoclavable, Easy Adjustment, Quick and Simple Maintenance
- 354 – The Tip of the Iceberg: How Pipette Tips Influence Results
- Accelerate 384-Well Pipetting
- Checklist for a More Sustainable Lab
- Maintenance of Eppendorf Research® plus pipettes
- Pipetting Techniques
- Transferring Non-Aqueous Liquids
Technical Documents
- 384. Ready. Set. Pipette!
- Calibration Done Right
- Get It Right! Selection Chart for Liquid Handling Instruments & Tips
- Increase Your Pipetting Productivity Today
- Natural Winners
- Pipette Service
- Pipette Service Done Right
- ACT - Research plus pipettes, single-channel, variable volume
- Grease for Pipettes
- Change Filter
- Chemical Resistance - Eppendorf Research® plus
- Combination of epT.I.P.S.® Pipette Tips with Eppendorf Pipettes
- Eppendorf Research® plus
- Eppendorf Research® plus - Factory Adjustment
- Eppendorf Research® plus - Temporary Adjustment
- Eppendorf Research® plus Spec Sheet
- Grease for Pipettes
- Locking Clips for Multi-Channel Lower Parts
- Pipette Service Form
- Standard operating procedure for manual dispensing systems
- 019 – Fundamentals of Dispensing
- 020 – Impact of Pipetting Techniques on Precision and Accuracy
- 021 – Influence of physical parameters on the dispensed volume of air-cushion pipette
- 024 – Cleaning and Inspection of Pipettes
- 025 – Calibration and Adjustment of Dispensing Systems in the Laboratory
- 035 – Five Challenges in Plate Assays that Can Be Mastered by the Right Choice of Pipetting Tool
- 046 – The Eppendorf PhysioCare Concept® - 3 Spheres Model
- 071 – How Can I Improve Sustainability in My Lab?
- 082 – What Really Matters
- 085 – Requirements and Eppendorf Solutions for Immunological Analyses
- 16- and 24-Channel Pipettes and epT.I.P.S.® 384
- 197 – The Eppendorf Research® plus Pipette - Lightweight, Reliable and Ergonomic
- 198 – The Eppendorf Mechanical Pipettes Research® plus and Reference® 2 – Fully Autoclavable, Easy Adjustment, Quick and Simple Maintenance
- 354 – The Tip of the Iceberg: How Pipette Tips Influence Results
- Accelerate 384-Well Pipetting
- Checklist for a More Sustainable Lab
- Maintenance of Eppendorf Research® plus pipettes
- Pipetting Techniques
- Transferring Non-Aqueous Liquids
Technical Documents
- 384. Ready. Set. Pipette!
- Calibration Done Right
- Get It Right! Selection Chart for Liquid Handling Instruments & Tips
- Increase Your Pipetting Productivity Today
- Natural Winners
- Pipette Service
- Pipette Service Done Right
- ACT - Research plus pipette, 0.5-10 μL (medium gray), single-channel, variable
- ACT - Research plus pipettes, single-channel, variable volume
- Grease for Pipettes
- Change Filter
- Chemical Resistance - Eppendorf Research® plus
- Combination of epT.I.P.S.® Pipette Tips with Eppendorf Pipettes
- Eppendorf Research® plus
- Eppendorf Research® plus - Factory Adjustment
- Eppendorf Research® plus - Temporary Adjustment
- Eppendorf Research® plus Spec Sheet
- Grease for Pipettes
- Locking Clips for Multi-Channel Lower Parts
- Pipette Service Form
- Standard operating procedure for manual dispensing systems
- 019 – Fundamentals of Dispensing
- 020 – Impact of Pipetting Techniques on Precision and Accuracy
- 021 – Influence of physical parameters on the dispensed volume of air-cushion pipette
- 024 – Cleaning and Inspection of Pipettes
- 025 – Calibration and Adjustment of Dispensing Systems in the Laboratory
- 035 – Five Challenges in Plate Assays that Can Be Mastered by the Right Choice of Pipetting Tool
- 046 – The Eppendorf PhysioCare Concept® - 3 Spheres Model
- 071 – How Can I Improve Sustainability in My Lab?
- 082 – What Really Matters
- 085 – Requirements and Eppendorf Solutions for Immunological Analyses
- 16- and 24-Channel Pipettes and epT.I.P.S.® 384
- 197 – The Eppendorf Research® plus Pipette - Lightweight, Reliable and Ergonomic
- 198 – The Eppendorf Mechanical Pipettes Research® plus and Reference® 2 – Fully Autoclavable, Easy Adjustment, Quick and Simple Maintenance
- 354 – The Tip of the Iceberg: How Pipette Tips Influence Results
- Accelerate 384-Well Pipetting
- Checklist for a More Sustainable Lab
- Maintenance of Eppendorf Research® plus pipettes
- Pipetting Techniques
- Transferring Non-Aqueous Liquids
Technical Documents
- 384. Ready. Set. Pipette!
- Calibration Done Right
- Get It Right! Selection Chart for Liquid Handling Instruments & Tips
- Increase Your Pipetting Productivity Today
- Natural Winners
- Pipette Service
- Pipette Service Done Right
- ACT - Research plus pipettes, single-channel, variable volume
- Grease for Pipettes
- Change Filter
- Chemical Resistance - Eppendorf Research® plus
- Combination of epT.I.P.S.® Pipette Tips with Eppendorf Pipettes
- Eppendorf Research® plus
- Eppendorf Research® plus - Factory Adjustment
- Eppendorf Research® plus - Temporary Adjustment
- Eppendorf Research® plus Spec Sheet
- Grease for Pipettes
- Locking Clips for Multi-Channel Lower Parts
- Pipette Service Form
- Standard operating procedure for manual dispensing systems
- 019 – Fundamentals of Dispensing
- 020 – Impact of Pipetting Techniques on Precision and Accuracy
- 021 – Influence of physical parameters on the dispensed volume of air-cushion pipette
- 024 – Cleaning and Inspection of Pipettes
- 025 – Calibration and Adjustment of Dispensing Systems in the Laboratory
- 035 – Five Challenges in Plate Assays that Can Be Mastered by the Right Choice of Pipetting Tool
- 046 – The Eppendorf PhysioCare Concept® - 3 Spheres Model
- 071 – How Can I Improve Sustainability in My Lab?
- 082 – What Really Matters
- 085 – Requirements and Eppendorf Solutions for Immunological Analyses
- 16- and 24-Channel Pipettes and epT.I.P.S.® 384
- 197 – The Eppendorf Research® plus Pipette - Lightweight, Reliable and Ergonomic
- 198 – The Eppendorf Mechanical Pipettes Research® plus and Reference® 2 – Fully Autoclavable, Easy Adjustment, Quick and Simple Maintenance
- 354 – The Tip of the Iceberg: How Pipette Tips Influence Results
- Accelerate 384-Well Pipetting
- Checklist for a More Sustainable Lab
- Maintenance of Eppendorf Research® plus pipettes
- Pipetting Techniques
- Transferring Non-Aqueous Liquids
Technical Documents
- 384. Ready. Set. Pipette!
- Calibration Done Right
- Get It Right! Selection Chart for Liquid Handling Instruments & Tips
- Increase Your Pipetting Productivity Today
- Natural Winners
- Pipette Service
- Pipette Service Done Right
- ACT - Research plus pipettes, single-channel, variable volume
- Grease for Pipettes
- Change Filter
- Chemical Resistance - Eppendorf Research® plus
- Combination of epT.I.P.S.® Pipette Tips with Eppendorf Pipettes
- Eppendorf Research® plus
- Eppendorf Research® plus - Factory Adjustment
- Eppendorf Research® plus - Temporary Adjustment
- Eppendorf Research® plus Spec Sheet
- Grease for Pipettes
- Locking Clips for Multi-Channel Lower Parts
- Pipette Service Form
- Standard operating procedure for manual dispensing systems
- 019 – Fundamentals of Dispensing
- 020 – Impact of Pipetting Techniques on Precision and Accuracy
- 021 – Influence of physical parameters on the dispensed volume of air-cushion pipette
- 024 – Cleaning and Inspection of Pipettes
- 025 – Calibration and Adjustment of Dispensing Systems in the Laboratory
- 035 – Five Challenges in Plate Assays that Can Be Mastered by the Right Choice of Pipetting Tool
- 046 – The Eppendorf PhysioCare Concept® - 3 Spheres Model
- 071 – How Can I Improve Sustainability in My Lab?
- 082 – What Really Matters
- 085 – Requirements and Eppendorf Solutions for Immunological Analyses
- 16- and 24-Channel Pipettes and epT.I.P.S.® 384
- 197 – The Eppendorf Research® plus Pipette - Lightweight, Reliable and Ergonomic
- 198 – The Eppendorf Mechanical Pipettes Research® plus and Reference® 2 – Fully Autoclavable, Easy Adjustment, Quick and Simple Maintenance
- 354 – The Tip of the Iceberg: How Pipette Tips Influence Results
- Accelerate 384-Well Pipetting
- Checklist for a More Sustainable Lab
- Maintenance of Eppendorf Research® plus pipettes
- Pipetting Techniques
- Transferring Non-Aqueous Liquids
Technical Documents
- 384. Ready. Set. Pipette!
- Calibration Done Right
- Get It Right! Selection Chart for Liquid Handling Instruments & Tips
- Increase Your Pipetting Productivity Today
- Natural Winners
- Pipette Service
- Pipette Service Done Right
- ACT - Research plus pipette, 20-200 μL (yellow), single-channel, variable
- ACT - Research plus pipettes, single-channel, variable volume
- Grease for Pipettes
- Change Filter
- Chemical Resistance - Eppendorf Research® plus
- Combination of epT.I.P.S.® Pipette Tips with Eppendorf Pipettes
- Eppendorf Research® plus
- Eppendorf Research® plus - Factory Adjustment
- Eppendorf Research® plus - Temporary Adjustment
- Eppendorf Research® plus Spec Sheet
- Grease for Pipettes
- Locking Clips for Multi-Channel Lower Parts
- Pipette Service Form
- Standard operating procedure for manual dispensing systems
- 019 – Fundamentals of Dispensing
- 020 – Impact of Pipetting Techniques on Precision and Accuracy
- 021 – Influence of physical parameters on the dispensed volume of air-cushion pipette
- 024 – Cleaning and Inspection of Pipettes
- 025 – Calibration and Adjustment of Dispensing Systems in the Laboratory
- 035 – Five Challenges in Plate Assays that Can Be Mastered by the Right Choice of Pipetting Tool
- 046 – The Eppendorf PhysioCare Concept® - 3 Spheres Model
- 071 – How Can I Improve Sustainability in My Lab?
- 082 – What Really Matters
- 085 – Requirements and Eppendorf Solutions for Immunological Analyses
- 16- and 24-Channel Pipettes and epT.I.P.S.® 384
- 197 – The Eppendorf Research® plus Pipette - Lightweight, Reliable and Ergonomic
- 198 – The Eppendorf Mechanical Pipettes Research® plus and Reference® 2 – Fully Autoclavable, Easy Adjustment, Quick and Simple Maintenance
- 354 – The Tip of the Iceberg: How Pipette Tips Influence Results
- Accelerate 384-Well Pipetting
- Checklist for a More Sustainable Lab
- Maintenance of Eppendorf Research® plus pipettes
- Pipetting Techniques
- Transferring Non-Aqueous Liquids
Technical Documents
- 384. Ready. Set. Pipette!
- Calibration Done Right
- Get It Right! Selection Chart for Liquid Handling Instruments & Tips
- Increase Your Pipetting Productivity Today
- Natural Winners
- Pipette Service
- Pipette Service Done Right
- ACT - Research plus pipette, 2-20 μL (yellow), single-channel, variable
- ACT - Research plus pipettes, single-channel, variable volume
- Grease for Pipettes
- Change Filter
- Chemical Resistance - Eppendorf Research® plus
- Combination of epT.I.P.S.® Pipette Tips with Eppendorf Pipettes
- Eppendorf Research® plus
- Eppendorf Research® plus - Factory Adjustment
- Eppendorf Research® plus - Temporary Adjustment
- Eppendorf Research® plus Spec Sheet
- Grease for Pipettes
- Locking Clips for Multi-Channel Lower Parts
- Pipette Service Form
- Standard operating procedure for manual dispensing systems
- 019 – Fundamentals of Dispensing
- 020 – Impact of Pipetting Techniques on Precision and Accuracy
- 021 – Influence of physical parameters on the dispensed volume of air-cushion pipette
- 024 – Cleaning and Inspection of Pipettes
- 025 – Calibration and Adjustment of Dispensing Systems in the Laboratory
- 035 – Five Challenges in Plate Assays that Can Be Mastered by the Right Choice of Pipetting Tool
- 046 – The Eppendorf PhysioCare Concept® - 3 Spheres Model
- 071 – How Can I Improve Sustainability in My Lab?
- 082 – What Really Matters
- 085 – Requirements and Eppendorf Solutions for Immunological Analyses
- 16- and 24-Channel Pipettes and epT.I.P.S.® 384
- 197 – The Eppendorf Research® plus Pipette - Lightweight, Reliable and Ergonomic
- 198 – The Eppendorf Mechanical Pipettes Research® plus and Reference® 2 – Fully Autoclavable, Easy Adjustment, Quick and Simple Maintenance
- 354 – The Tip of the Iceberg: How Pipette Tips Influence Results
- Accelerate 384-Well Pipetting
- Checklist for a More Sustainable Lab
- Maintenance of Eppendorf Research® plus pipettes
- Pipetting Techniques
- Transferring Non-Aqueous Liquids
Technical Documents
- 384. Ready. Set. Pipette!
- Calibration Done Right
- Get It Right! Selection Chart for Liquid Handling Instruments & Tips
- Increase Your Pipetting Productivity Today
- Natural Winners
- Pipette Service
- Pipette Service Done Right
- ACT - Research plus pipettes, single-channel, variable volume
- Grease for Pipettes
- Change Filter
- Chemical Resistance - Eppendorf Research® plus
- Combination of epT.I.P.S.® Pipette Tips with Eppendorf Pipettes
- Eppendorf Research® plus
- Eppendorf Research® plus - Factory Adjustment
- Eppendorf Research® plus - Temporary Adjustment
- Eppendorf Research® plus Spec Sheet
- Grease for Pipettes
- Locking Clips for Multi-Channel Lower Parts
- Pipette Service Form
- Standard operating procedure for manual dispensing systems
- 019 – Fundamentals of Dispensing
- 020 – Impact of Pipetting Techniques on Precision and Accuracy
- 021 – Influence of physical parameters on the dispensed volume of air-cushion pipette
- 024 – Cleaning and Inspection of Pipettes
- 025 – Calibration and Adjustment of Dispensing Systems in the Laboratory
- 035 – Five Challenges in Plate Assays that Can Be Mastered by the Right Choice of Pipetting Tool
- 046 – The Eppendorf PhysioCare Concept® - 3 Spheres Model
- 071 – How Can I Improve Sustainability in My Lab?
- 082 – What Really Matters
- 085 – Requirements and Eppendorf Solutions for Immunological Analyses
- 16- and 24-Channel Pipettes and epT.I.P.S.® 384
- 197 – The Eppendorf Research® plus Pipette - Lightweight, Reliable and Ergonomic
- 198 – The Eppendorf Mechanical Pipettes Research® plus and Reference® 2 – Fully Autoclavable, Easy Adjustment, Quick and Simple Maintenance
- 354 – The Tip of the Iceberg: How Pipette Tips Influence Results
- Accelerate 384-Well Pipetting
- Checklist for a More Sustainable Lab
- Maintenance of Eppendorf Research® plus pipettes
- Pipetting Techniques
- Transferring Non-Aqueous Liquids
Technical Documents
- 384. Ready. Set. Pipette!
- Calibration Done Right
- Get It Right! Selection Chart for Liquid Handling Instruments & Tips
- Increase Your Pipetting Productivity Today
- Natural Winners
- Pipette Service
- Pipette Service Done Right
- ACT - Research plus pipette, 0.25-2.5 mL (red), single-channel, variable
- ACT - Research plus pipettes, single-channel, variable volume
- Grease for Pipettes
- Change Filter
- Chemical Resistance - Eppendorf Research® plus
- Combination of epT.I.P.S.® Pipette Tips with Eppendorf Pipettes
- Eppendorf Research® plus
- Eppendorf Research® plus - Factory Adjustment
- Eppendorf Research® plus - Temporary Adjustment
- Eppendorf Research® plus Spec Sheet
- Grease for Pipettes
- Locking Clips for Multi-Channel Lower Parts
- Pipette Service Form
- Standard operating procedure for manual dispensing systems
- 019 – Fundamentals of Dispensing
- 020 – Impact of Pipetting Techniques on Precision and Accuracy
- 021 – Influence of physical parameters on the dispensed volume of air-cushion pipette
- 024 – Cleaning and Inspection of Pipettes
- 025 – Calibration and Adjustment of Dispensing Systems in the Laboratory
- 035 – Five Challenges in Plate Assays that Can Be Mastered by the Right Choice of Pipetting Tool
- 046 – The Eppendorf PhysioCare Concept® - 3 Spheres Model
- 071 – How Can I Improve Sustainability in My Lab?
- 082 – What Really Matters
- 085 – Requirements and Eppendorf Solutions for Immunological Analyses
- 16- and 24-Channel Pipettes and epT.I.P.S.® 384
- 197 – The Eppendorf Research® plus Pipette - Lightweight, Reliable and Ergonomic
- 198 – The Eppendorf Mechanical Pipettes Research® plus and Reference® 2 – Fully Autoclavable, Easy Adjustment, Quick and Simple Maintenance
- 354 – The Tip of the Iceberg: How Pipette Tips Influence Results
- Accelerate 384-Well Pipetting
- Checklist for a More Sustainable Lab
- Maintenance of Eppendorf Research® plus pipettes
- Pipetting Techniques
- Transferring Non-Aqueous Liquids
Technical Documents
- 384. Ready. Set. Pipette!
- Calibration Done Right
- Get It Right! Selection Chart for Liquid Handling Instruments & Tips
- Increase Your Pipetting Productivity Today
- Natural Winners
- Pipette Service
- Pipette Service Done Right
- ACT - Research plus pipette, 10-100 μL (yellow), single-channel, variable
- ACT - Research plus pipettes, single-channel, variable volume
- Grease for Pipettes
- Change Filter
- Chemical Resistance - Eppendorf Research® plus
- Combination of epT.I.P.S.® Pipette Tips with Eppendorf Pipettes
- Eppendorf Research® plus
- Eppendorf Research® plus - Factory Adjustment
- Eppendorf Research® plus - Temporary Adjustment
- Eppendorf Research® plus Spec Sheet
- Grease for Pipettes
- Locking Clips for Multi-Channel Lower Parts
- Pipette Service Form
- Standard operating procedure for manual dispensing systems
- 019 – Fundamentals of Dispensing
- 020 – Impact of Pipetting Techniques on Precision and Accuracy
- 021 – Influence of physical parameters on the dispensed volume of air-cushion pipette
- 024 – Cleaning and Inspection of Pipettes
- 025 – Calibration and Adjustment of Dispensing Systems in the Laboratory
- 035 – Five Challenges in Plate Assays that Can Be Mastered by the Right Choice of Pipetting Tool
- 046 – The Eppendorf PhysioCare Concept® - 3 Spheres Model
- 071 – How Can I Improve Sustainability in My Lab?
- 082 – What Really Matters
- 085 – Requirements and Eppendorf Solutions for Immunological Analyses
- 16- and 24-Channel Pipettes and epT.I.P.S.® 384
- 197 – The Eppendorf Research® plus Pipette - Lightweight, Reliable and Ergonomic
- 198 – The Eppendorf Mechanical Pipettes Research® plus and Reference® 2 – Fully Autoclavable, Easy Adjustment, Quick and Simple Maintenance
- 354 – The Tip of the Iceberg: How Pipette Tips Influence Results
- Accelerate 384-Well Pipetting
- Checklist for a More Sustainable Lab
- Maintenance of Eppendorf Research® plus pipettes
- Pipetting Techniques
- Transferring Non-Aqueous Liquids
Technical Documents
- 384. Ready. Set. Pipette!
- Calibration Done Right
- Get It Right! Selection Chart for Liquid Handling Instruments & Tips
- Increase Your Pipetting Productivity Today
- Natural Winners
- Pipette Service
- Pipette Service Done Right
- ACT - Research plus pipette, 100-1000 μL (blue), single-channel, variable
- ACT - Research plus pipettes, single-channel, variable volume
- Grease for Pipettes
- Change Filter
- Chemical Resistance - Eppendorf Research® plus
- Combination of epT.I.P.S.® Pipette Tips with Eppendorf Pipettes
- Eppendorf Research® plus
- Eppendorf Research® plus - Factory Adjustment
- Eppendorf Research® plus - Temporary Adjustment
- Eppendorf Research® plus Spec Sheet
- Grease for Pipettes
- Locking Clips for Multi-Channel Lower Parts
- Pipette Service Form
- Standard operating procedure for manual dispensing systems
- 019 – Fundamentals of Dispensing
- 020 – Impact of Pipetting Techniques on Precision and Accuracy
- 021 – Influence of physical parameters on the dispensed volume of air-cushion pipette
- 024 – Cleaning and Inspection of Pipettes
- 025 – Calibration and Adjustment of Dispensing Systems in the Laboratory
- 035 – Five Challenges in Plate Assays that Can Be Mastered by the Right Choice of Pipetting Tool
- 046 – The Eppendorf PhysioCare Concept® - 3 Spheres Model
- 071 – How Can I Improve Sustainability in My Lab?
- 082 – What Really Matters
- 085 – Requirements and Eppendorf Solutions for Immunological Analyses
- 16- and 24-Channel Pipettes and epT.I.P.S.® 384
- 197 – The Eppendorf Research® plus Pipette - Lightweight, Reliable and Ergonomic
- 198 – The Eppendorf Mechanical Pipettes Research® plus and Reference® 2 – Fully Autoclavable, Easy Adjustment, Quick and Simple Maintenance
- 354 – The Tip of the Iceberg: How Pipette Tips Influence Results
- Accelerate 384-Well Pipetting
- Checklist for a More Sustainable Lab
- Maintenance of Eppendorf Research® plus pipettes
- Pipetting Techniques
- Transferring Non-Aqueous Liquids
Technical Documents
- 384. Ready. Set. Pipette!
- Calibration Done Right
- Get It Right! Selection Chart for Liquid Handling Instruments & Tips
- Increase Your Pipetting Productivity Today
- Natural Winners
- Pipette Service
- Pipette Service Done Right
- ACT - Research plus pipette, 0.5-5 mL (violet), single-channel, variable
- ACT - Research plus pipettes, single-channel, variable volume
- Grease for Pipettes
- Change Filter
- Chemical Resistance - Eppendorf Research® plus
- Combination of epT.I.P.S.® Pipette Tips with Eppendorf Pipettes
- Eppendorf Research® plus
- Eppendorf Research® plus - Factory Adjustment
- Eppendorf Research® plus - Temporary Adjustment
- Eppendorf Research® plus Spec Sheet
- Grease for Pipettes
- Locking Clips for Multi-Channel Lower Parts
- Pipette Service Form
- Standard operating procedure for manual dispensing systems
- 019 – Fundamentals of Dispensing
- 020 – Impact of Pipetting Techniques on Precision and Accuracy
- 021 – Influence of physical parameters on the dispensed volume of air-cushion pipette
- 024 – Cleaning and Inspection of Pipettes
- 025 – Calibration and Adjustment of Dispensing Systems in the Laboratory
- 035 – Five Challenges in Plate Assays that Can Be Mastered by the Right Choice of Pipetting Tool
- 046 – The Eppendorf PhysioCare Concept® - 3 Spheres Model
- 071 – How Can I Improve Sustainability in My Lab?
- 082 – What Really Matters
- 085 – Requirements and Eppendorf Solutions for Immunological Analyses
- 16- and 24-Channel Pipettes and epT.I.P.S.® 384
- 197 – The Eppendorf Research® plus Pipette - Lightweight, Reliable and Ergonomic
- 198 – The Eppendorf Mechanical Pipettes Research® plus and Reference® 2 – Fully Autoclavable, Easy Adjustment, Quick and Simple Maintenance
- 354 – The Tip of the Iceberg: How Pipette Tips Influence Results
- Accelerate 384-Well Pipetting
- Checklist for a More Sustainable Lab
- Maintenance of Eppendorf Research® plus pipettes
- Pipetting Techniques
- Transferring Non-Aqueous Liquids
Technical Documents
- 384. Ready. Set. Pipette!
- Calibration Done Right
- Get It Right! Selection Chart for Liquid Handling Instruments & Tips
- Increase Your Pipetting Productivity Today
- Natural Winners
- Pipette Service
- Pipette Service Done Right
- ACT - Research plus pipette, 2-20 μL (light gray), single-channel, variable
- ACT - Research plus pipettes, single-channel, variable volume
- Grease for Pipettes
- Change Filter
- Chemical Resistance - Eppendorf Research® plus
- Combination of epT.I.P.S.® Pipette Tips with Eppendorf Pipettes
- Eppendorf Research® plus
- Eppendorf Research® plus - Factory Adjustment
- Eppendorf Research® plus - Temporary Adjustment
- Eppendorf Research® plus Spec Sheet
- Grease for Pipettes
- Locking Clips for Multi-Channel Lower Parts
- Pipette Service Form
- Standard operating procedure for manual dispensing systems
- 019 – Fundamentals of Dispensing
- 020 – Impact of Pipetting Techniques on Precision and Accuracy
- 021 – Influence of physical parameters on the dispensed volume of air-cushion pipette
- 024 – Cleaning and Inspection of Pipettes
- 025 – Calibration and Adjustment of Dispensing Systems in the Laboratory
- 035 – Five Challenges in Plate Assays that Can Be Mastered by the Right Choice of Pipetting Tool
- 046 – The Eppendorf PhysioCare Concept® - 3 Spheres Model
- 071 – How Can I Improve Sustainability in My Lab?
- 082 – What Really Matters
- 085 – Requirements and Eppendorf Solutions for Immunological Analyses
- 16- and 24-Channel Pipettes and epT.I.P.S.® 384
- 197 – The Eppendorf Research® plus Pipette - Lightweight, Reliable and Ergonomic
- 198 – The Eppendorf Mechanical Pipettes Research® plus and Reference® 2 – Fully Autoclavable, Easy Adjustment, Quick and Simple Maintenance
- 354 – The Tip of the Iceberg: How Pipette Tips Influence Results
- Accelerate 384-Well Pipetting
- Checklist for a More Sustainable Lab
- Maintenance of Eppendorf Research® plus pipettes
- Pipetting Techniques
- Transferring Non-Aqueous Liquids
Technical Documents
- 384. Ready. Set. Pipette!
- Calibration Done Right
- Get It Right! Selection Chart for Liquid Handling Instruments & Tips
- Increase Your Pipetting Productivity Today
- Natural Winners
- Pipette Service
- Pipette Service Done Right
- ACT - Research plus pipettes, single-channel, variable volume
- Grease for Pipettes
- Change Filter
- Chemical Resistance - Eppendorf Research® plus
- Combination of epT.I.P.S.® Pipette Tips with Eppendorf Pipettes
- Eppendorf Research® plus
- Eppendorf Research® plus - Factory Adjustment
- Eppendorf Research® plus - Temporary Adjustment
- Eppendorf Research® plus Spec Sheet
- Grease for Pipettes
- Locking Clips for Multi-Channel Lower Parts
- Pipette Service Form
- Standard operating procedure for manual dispensing systems
- 019 – Fundamentals of Dispensing
- 020 – Impact of Pipetting Techniques on Precision and Accuracy
- 021 – Influence of physical parameters on the dispensed volume of air-cushion pipette
- 024 – Cleaning and Inspection of Pipettes
- 025 – Calibration and Adjustment of Dispensing Systems in the Laboratory
- 035 – Five Challenges in Plate Assays that Can Be Mastered by the Right Choice of Pipetting Tool
- 046 – The Eppendorf PhysioCare Concept® - 3 Spheres Model
- 071 – How Can I Improve Sustainability in My Lab?
- 082 – What Really Matters
- 085 – Requirements and Eppendorf Solutions for Immunological Analyses
- 16- and 24-Channel Pipettes and epT.I.P.S.® 384
- 197 – The Eppendorf Research® plus Pipette - Lightweight, Reliable and Ergonomic
- 198 – The Eppendorf Mechanical Pipettes Research® plus and Reference® 2 – Fully Autoclavable, Easy Adjustment, Quick and Simple Maintenance
- 354 – The Tip of the Iceberg: How Pipette Tips Influence Results
- Accelerate 384-Well Pipetting
- Checklist for a More Sustainable Lab
- Maintenance of Eppendorf Research® plus pipettes
- Pipetting Techniques
- Transferring Non-Aqueous Liquids
Technical Documents
- 384. Ready. Set. Pipette!
- Calibration Done Right
- Get It Right! Selection Chart for Liquid Handling Instruments & Tips
- Increase Your Pipetting Productivity Today
- Natural Winners
- Pipette Service
- Pipette Service Done Right
- ACT - Research plus pipette, 30-300 μL (orange), single-channel, variable
- ACT - Research plus pipettes, single-channel, variable volume
- Grease for Pipettes
- Change Filter
- Chemical Resistance - Eppendorf Research® plus
- Combination of epT.I.P.S.® Pipette Tips with Eppendorf Pipettes
- Eppendorf Research® plus
- Eppendorf Research® plus - Factory Adjustment
- Eppendorf Research® plus - Temporary Adjustment
- Eppendorf Research® plus Spec Sheet
- Grease for Pipettes
- Locking Clips for Multi-Channel Lower Parts
- Pipette Service Form
- Standard operating procedure for manual dispensing systems
- 019 – Fundamentals of Dispensing
- 020 – Impact of Pipetting Techniques on Precision and Accuracy
- 021 – Influence of physical parameters on the dispensed volume of air-cushion pipette
- 024 – Cleaning and Inspection of Pipettes
- 025 – Calibration and Adjustment of Dispensing Systems in the Laboratory
- 035 – Five Challenges in Plate Assays that Can Be Mastered by the Right Choice of Pipetting Tool
- 046 – The Eppendorf PhysioCare Concept® - 3 Spheres Model
- 071 – How Can I Improve Sustainability in My Lab?
- 082 – What Really Matters
- 085 – Requirements and Eppendorf Solutions for Immunological Analyses
- 16- and 24-Channel Pipettes and epT.I.P.S.® 384
- 197 – The Eppendorf Research® plus Pipette - Lightweight, Reliable and Ergonomic
- 198 – The Eppendorf Mechanical Pipettes Research® plus and Reference® 2 – Fully Autoclavable, Easy Adjustment, Quick and Simple Maintenance
- 354 – The Tip of the Iceberg: How Pipette Tips Influence Results
- Accelerate 384-Well Pipetting
- Checklist for a More Sustainable Lab
- Maintenance of Eppendorf Research® plus pipettes
- Pipetting Techniques
- Transferring Non-Aqueous Liquids
Technical Documents
- 384. Ready. Set. Pipette!
- Calibration Done Right
- Get It Right! Selection Chart for Liquid Handling Instruments & Tips
- Increase Your Pipetting Productivity Today
- Natural Winners
- Pipette Service
- Pipette Service Done Right
- ACT - Research plus pipettes, single-channel, variable volume
- Grease for Pipettes
- Change Filter
- Chemical Resistance - Eppendorf Research® plus
- Combination of epT.I.P.S.® Pipette Tips with Eppendorf Pipettes
- Eppendorf Research® plus
- Eppendorf Research® plus - Factory Adjustment
- Eppendorf Research® plus - Temporary Adjustment
- Eppendorf Research® plus Spec Sheet
- Grease for Pipettes
- Locking Clips for Multi-Channel Lower Parts
- Pipette Service Form
- Standard operating procedure for manual dispensing systems
- 019 – Fundamentals of Dispensing
- 020 – Impact of Pipetting Techniques on Precision and Accuracy
- 021 – Influence of physical parameters on the dispensed volume of air-cushion pipette
- 024 – Cleaning and Inspection of Pipettes
- 025 – Calibration and Adjustment of Dispensing Systems in the Laboratory
- 035 – Five Challenges in Plate Assays that Can Be Mastered by the Right Choice of Pipetting Tool
- 046 – The Eppendorf PhysioCare Concept® - 3 Spheres Model
- 071 – How Can I Improve Sustainability in My Lab?
- 082 – What Really Matters
- 085 – Requirements and Eppendorf Solutions for Immunological Analyses
- 16- and 24-Channel Pipettes and epT.I.P.S.® 384
- 197 – The Eppendorf Research® plus Pipette - Lightweight, Reliable and Ergonomic
- 198 – The Eppendorf Mechanical Pipettes Research® plus and Reference® 2 – Fully Autoclavable, Easy Adjustment, Quick and Simple Maintenance
- 354 – The Tip of the Iceberg: How Pipette Tips Influence Results
- Accelerate 384-Well Pipetting
- Checklist for a More Sustainable Lab
- Maintenance of Eppendorf Research® plus pipettes
- Pipetting Techniques
- Transferring Non-Aqueous Liquids
Technical Documents
- 384. Ready. Set. Pipette!
- Calibration Done Right
- Get It Right! Selection Chart for Liquid Handling Instruments & Tips
- Increase Your Pipetting Productivity Today
- Natural Winners
- Pipette Service
- Pipette Service Done Right
- ACT - Research plus pipettes, single-channel, variable volume
- Grease for Pipettes
- Change Filter
- Chemical Resistance - Eppendorf Research® plus
- Combination of epT.I.P.S.® Pipette Tips with Eppendorf Pipettes
- Eppendorf Research® plus
- Eppendorf Research® plus - Factory Adjustment
- Eppendorf Research® plus - Temporary Adjustment
- Eppendorf Research® plus Spec Sheet
- Grease for Pipettes
- Locking Clips for Multi-Channel Lower Parts
- Pipette Service Form
- Standard operating procedure for manual dispensing systems
- 019 – Fundamentals of Dispensing
- 020 – Impact of Pipetting Techniques on Precision and Accuracy
- 021 – Influence of physical parameters on the dispensed volume of air-cushion pipette
- 024 – Cleaning and Inspection of Pipettes
- 025 – Calibration and Adjustment of Dispensing Systems in the Laboratory
- 035 – Five Challenges in Plate Assays that Can Be Mastered by the Right Choice of Pipetting Tool
- 046 – The Eppendorf PhysioCare Concept® - 3 Spheres Model
- 071 – How Can I Improve Sustainability in My Lab?
- 082 – What Really Matters
- 085 – Requirements and Eppendorf Solutions for Immunological Analyses
- 16- and 24-Channel Pipettes and epT.I.P.S.® 384
- 197 – The Eppendorf Research® plus Pipette - Lightweight, Reliable and Ergonomic
- 198 – The Eppendorf Mechanical Pipettes Research® plus and Reference® 2 – Fully Autoclavable, Easy Adjustment, Quick and Simple Maintenance
- 354 – The Tip of the Iceberg: How Pipette Tips Influence Results
- Accelerate 384-Well Pipetting
- Checklist for a More Sustainable Lab
- Maintenance of Eppendorf Research® plus pipettes
- Pipetting Techniques
- Transferring Non-Aqueous Liquids
Detailed Description
The Eppendorf Research Plus pipette is the most advanced and ergonomic pipette available from Eppendorf. The pipette has been designed from the ground up to be the lightest and most ergonomic pipette while still maintaining the performance and robustness you have come to expect from Eppendorf. The ultra light Eppendorf Research plus pipette meets the highest needs in precision and accuracy – combined with ultimate ergonomics and increased flexibility.
Citations
23 Product Options
Catalog Number:
86-121
List Price:
$1972.24
Your Price:
$1690.49
Specifications:
Volume | 10 to 100 μL |
Number of Channels | 12-Channel |
Description | Variable Volume, 10-100µl |
Qty/Unit | 1 Pipettor/Unit |
Catalog Number:
86-2840
List Price:
$1969.81
Your Price:
$1688.41
Specifications:
Volume | 50 to 1200 µl |
Number of Channels | 12-Channel |
Description | Variable Volume, 50 - 1200ul |
Qty/Unit | 1 Pipettor/Unit |
Catalog Number:
86-105
List Price:
$722.19
Your Price:
$619.02
Specifications:
Volume | 0.1 to 2.5 μL |
Number of Channels | Single-Channel |
Description | For Use With 10µl Tips |
Qty/Unit | 1 Pipettor/Unit |
Catalog Number:
86-2860
List Price:
$2208.79
Your Price:
$1893.25
Specifications:
Volume | 1 to 20 µl |
Number of Channels | 16-Channel |
Description | Variable Volume, 1 - 20µl |
Qty/Unit | 1 Pipettor/Unit |
Catalog Number:
86-2833
List Price:
$1695.78
Your Price:
$1453.52
Specifications:
Volume | 120 to 1200 μL |
Number of Channels | 8-Channel |
Description | Variable Volumes, 120-1200µl |
Qty/Unit | 1 Pipettor/Unit |
Catalog Number:
86-112
List Price:
$714.83
Your Price:
$612.71
Specifications:
Volume | 1000 to 10,000 μL |
Number of Channels | Single-Channel |
Description | For Use With 10ml Tips |
Qty/Unit | 1 Pipettor/Unit |
Catalog Number:
86-2863
List Price:
$2414.5
Your Price:
$2069.57
Specifications:
Volume | 5 to 100 μL |
Number of Channels | 24-Channel |
Description | Variable Volume, 5 - 100µl |
Qty/Unit | 1 Pipettor/Unit |
Catalog Number:
86-2861
List Price:
$2428.31
Your Price:
$2081.41
Specifications:
Volume | 1 to 20 µl |
Number of Channels | 24-Channel |
Description | Variable Volume, 1 - 20µl |
Qty/Unit | 1 Pipettor/Unit |
Catalog Number:
86-106
List Price:
$714.5
Your Price:
$612.43
Specifications:
Volume | 0.5 to 10 μL |
Number of Channels | Single-Channel |
Description | For Use With 10µl Tips |
Qty/Unit | 1 Pipettor/Unit |
Catalog Number:
86-2862
List Price:
$2208.79
Your Price:
$1893.25
Specifications:
Volume | 5 to 100 μL |
Number of Channels | 16-Channel |
Description | Variable Volume, 5 - 100µl |
Qty/Unit | 1 Pipettor/Unit |
Catalog Number:
86-122
List Price:
$1699.21
Your Price:
$1456.46
Specifications:
Volume | 30 to 300 μL |
Number of Channels | 8-Channel |
Description | Variable Volumes, 30-300µl |
Qty/Unit | 1 Pipettor/Unit |
Catalog Number:
86-109
List Price:
$722.19
Your Price:
$619.02
Specifications:
Volume | 20 to 200 μL |
Number of Channels | Single-Channel |
Description | For Use With 200µl Tips |
Qty/Unit | 1 Pipettor/Unit |
Catalog Number:
86-107
List Price:
$722.54
Your Price:
$619.32
Specifications:
Volume | 2 to 20 μL |
Number of Channels | Single-Channel |
Description | For Use With 200µl Tips |
Qty/Unit | 1 Pipettor/Unit |
Catalog Number:
86-119
List Price:
$1972.24
Your Price:
$1690.49
Specifications:
Volume | 0.5 to 10 μL |
Number of Channels | 12-Channel |
Description | Variable Volume, 0.5-10µl |
Qty/Unit | 1 Pipettor/Unit |
Catalog Number:
86-105S
List Price:
$733.43
Your Price:
$628.66
Specifications:
Volume | 0.25 to 2.5 µl |
Number of Channels | Single-Channel |
Description | Includes epT.I.P.S. Sample Bag |
Qty/Unit | 1 Pipettor/Unit |
Catalog Number:
86-108
List Price:
$722.19
Your Price:
$619.02
Specifications:
Volume | 10 to 100 μL |
Number of Channels | Single-Channel |
Description | For Use With 200µl Tips |
Qty/Unit | 1 Pipettor/Unit |
Catalog Number:
86-110
List Price:
$732.24
Your Price:
$627.64
Specifications:
Volume | 100 to 1000 μL |
Number of Channels | Single-Channel |
Description | For Use With 1000µl Tips |
Qty/Unit | 1 Pipettor/Unit |
Catalog Number:
86-111
List Price:
$714.48
Your Price:
$612.41
Specifications:
Volume | 500 to 5000 μL |
Number of Channels | Single-Channel |
Description | For Use With 5ml Tips |
Qty/Unit | 1 Pipettor/Unit |
Catalog Number:
86-113
List Price:
$722.16
Your Price:
$619
Specifications:
Volume | 20 to 200 µl (10XL tip Compatible) |
Number of Channels | Single-Channel |
Description | For Use With 10XL Tips |
Qty/Unit | 1 Pipettor/Unit |
Catalog Number:
86-118
List Price:
$1699.21
Your Price:
$1456.46
Specifications:
Volume | 0.5 to 10 μL |
Number of Channels | 8-Channel |
Description | Variable Volume, 0.5-10µl |
Qty/Unit | 1 Pipettor/Unit |
Catalog Number:
86-114
List Price:
$734.55
Your Price:
$629.62
Specifications:
Volume | 30 to 300 μL |
Number of Channels | Single-Channel |
Description | For Use With 300µl Tips |
Qty/Unit | 1 Pipettor/Unit |
Catalog Number:
86-120
List Price:
$1699.21
Your Price:
$1456.46
Specifications:
Volume | 10 to 100 μL |
Number of Channels | 8-Channel |
Description | Variable Volume, 10-100µl |
Qty/Unit | 1 Pipettor/Unit |
Catalog Number:
86-123
List Price:
$1972.24
Your Price:
$1690.49
Specifications:
Volume | 30 to 300 μL |
Number of Channels | 12-Channel |
Description | Variable Volume, 30-300µl |
Qty/Unit | 1 Pipettor/Unit |
Catalog # | Description | Qty/Unit | Volume | Number of Channels | Price (USD) | Quantity | Add to Order | |
---|---|---|---|---|---|---|---|---|
86-105 | For Use With 10µl Tips | 1 Pipettor/Unit | 0.1 to 2.5 μL | Single-Channel | ||||
86-105S | Includes epT.I.P.S. Sample Bag | 1 Pipettor/Unit | 0.25 to 2.5 µl | Single-Channel | ||||
86-106 | For Use With 10µl Tips | 1 Pipettor/Unit | 0.5 to 10 μL | Single-Channel | ||||
86-107 | For Use With 200µl Tips | 1 Pipettor/Unit | 2 to 20 μL | Single-Channel | ||||
86-108 | For Use With 200µl Tips | 1 Pipettor/Unit | 10 to 100 μL | Single-Channel | ||||
86-109 | For Use With 200µl Tips | 1 Pipettor/Unit | 20 to 200 μL | Single-Channel | ||||
86-110 | For Use With 1000µl Tips | 1 Pipettor/Unit | 100 to 1000 μL | Single-Channel | ||||
86-111 | For Use With 5ml Tips | 1 Pipettor/Unit | 500 to 5000 μL | Single-Channel | ||||
86-112 | For Use With 10ml Tips | 1 Pipettor/Unit | 1000 to 10,000 μL | Single-Channel | ||||
86-113 | For Use With 10XL Tips | 1 Pipettor/Unit | 20 to 200 µl (10XL tip Compatible) | Single-Channel | ||||
86-114 | For Use With 300µl Tips | 1 Pipettor/Unit | 30 to 300 μL | Single-Channel | ||||
86-118 | Variable Volume, 0.5-10µl | 1 Pipettor/Unit | 0.5 to 10 μL | 8-Channel | ||||
86-119 | Variable Volume, 0.5-10µl | 1 Pipettor/Unit | 0.5 to 10 μL | 12-Channel | ||||
86-120 | Variable Volume, 10-100µl | 1 Pipettor/Unit | 10 to 100 μL | 8-Channel | ||||
86-121 | Variable Volume, 10-100µl | 1 Pipettor/Unit | 10 to 100 μL | 12-Channel | ||||
86-122 | Variable Volumes, 30-300µl | 1 Pipettor/Unit | 30 to 300 μL | 8-Channel | ||||
86-123 | Variable Volume, 30-300µl | 1 Pipettor/Unit | 30 to 300 μL | 12-Channel | ||||
86-2833 | Variable Volumes, 120-1200µl | 1 Pipettor/Unit | 120 to 1200 μL | 8-Channel | ||||
86-2840 | Variable Volume, 50 - 1200ul | 1 Pipettor/Unit | 50 to 1200 µl | 12-Channel | ||||
86-2860 | Variable Volume, 1 - 20µl | 1 Pipettor/Unit | 1 to 20 µl | 16-Channel | ||||
86-2861 | Variable Volume, 1 - 20µl | 1 Pipettor/Unit | 1 to 20 µl | 24-Channel | ||||
86-2862 | Variable Volume, 5 - 100µl | 1 Pipettor/Unit | 5 to 100 μL | 16-Channel | ||||
86-2863 | Variable Volume, 5 - 100µl | 1 Pipettor/Unit | 5 to 100 μL | 24-Channel |
Need help?
Call our product expert?
+1.800.789.5550
or
Contact Us
7:00am - 5:00pm PST
Monday - Friday
!