CAT#:
Eppendorf
Eppendorf Reference® 2 Pipettors
For Use With 300µl Tips, 1 Pipettor/Unit
For Use With 300µl Tips, 1 Pipettor/Unit
For Use With 200µl Tips, 1 Pipettor/Unit
For Use With 200µl Tips, 1 Pipettor/Unit
For Use With 1000µl Tips, 1 Pipettor/Unit
For Use With 5ml Tips, 1 Pipettor/Unit
For Use With 20µl Tips, 1 Pipettor/Unit
For Use With 200µl Tips, 1 Pipettor/Unit
For Use With 200µl Tips, 1 Pipettor/Unit
For Use With 10µl Tips, 1 Pipettor/Unit
For Use With 20µl Tips, 1 Pipettor/Unit
For Use With 200µl Tips, 1 Pipettor/Unit
For Use With 10ml Tips, 1 Pipettor/Unit
For Use With 20µl Tips, 1 Pipettor/Unit
For Use With 2500µl Tips, 1 Pipettor/Unit
For Use With 300µl Tips, 1 Pipettor/Unit
For Use With 20µl Tips, 1 Pipettor/Unit
17 product variations: View Options
Product Overview
- Unique one-button operation offers fast and ergonomic handling
- Spring loaded tip cone improves user to user reproducibility and ergonomics
- Secondary adjustment to adjust pipette to a liquid very different than water
- Quick connect lower part enables easy cleaning and maintenance of your pipette
- Outstanding precision and accuracy
- External edges made from stainless steel equip the pipette with outstanding robustness
- Embedded RFID chip contains all relevant data regarding the pipette
- 10 digit volume display with magnifying window
Product Overview
- Unique one-button operation offers fast and ergonomic handling
- Spring loaded tip cone improves user to user reproducibility and ergonomics
- Secondary adjustment to adjust pipette to a liquid very different than water
- Quick connect lower part enables easy cleaning and maintenance of your pipette
- Outstanding precision and accuracy
- External edges made from stainless steel equip the pipette with outstanding robustness
- Embedded RFID chip contains all relevant data regarding the pipette
- 19 digit volume display with magnifying window
Product Overview
- Unique one-button operation offers fast and ergonomic handling
- Spring loaded tip cone improves user to user reproducibility and ergonomics
- Secondary adjustment to adjust pipette to a liquid very different than water
- Quick connect lower part enables easy cleaning and maintenance of your pipette
- Outstanding precision and accuracy
- External edges made from stainless steel equip the pipette with outstanding robustness
- Embedded RFID chip contains all relevant data regarding the pipette
- 18 digit volume display with magnifying window
Product Overview
- Unique one-button operation offers fast and ergonomic handling
- Spring loaded tip cone improves user to user reproducibility and ergonomics
- Secondary adjustment to adjust pipette to a liquid very different than water
- Quick connect lower part enables easy cleaning and maintenance of your pipette
- Outstanding precision and accuracy
- External edges made from stainless steel equip the pipette with outstanding robustness
- Embedded RFID chip contains all relevant data regarding the pipette
- 17 digit volume display with magnifying window
Product Overview
- Unique one-button operation offers fast and ergonomic handling
- Spring loaded tip cone improves user to user reproducibility and ergonomics
- Secondary adjustment to adjust pipette to a liquid very different than water
- Quick connect lower part enables easy cleaning and maintenance of your pipette
- Outstanding precision and accuracy
- External edges made from stainless steel equip the pipette with outstanding robustness
- Embedded RFID chip contains all relevant data regarding the pipette
- 11 digit volume display with magnifying window
Product Overview
- Unique one-button operation offers fast and ergonomic handling
- Spring loaded tip cone improves user to user reproducibility and ergonomics
- Secondary adjustment to adjust pipette to a liquid very different than water
- Quick connect lower part enables easy cleaning and maintenance of your pipette
- Outstanding precision and accuracy
- External edges made from stainless steel equip the pipette with outstanding robustness
- Embedded RFID chip contains all relevant data regarding the pipette
- 13 digit volume display with magnifying window
Product Overview
- Unique one-button operation offers fast and ergonomic handling
- Spring loaded tip cone improves user to user reproducibility and ergonomics
- Secondary adjustment to adjust pipette to a liquid very different than water
- Quick connect lower part enables easy cleaning and maintenance of your pipette
- Outstanding precision and accuracy
- External edges made from stainless steel equip the pipette with outstanding robustness
- Embedded RFID chip contains all relevant data regarding the pipette
- 16 digit volume display with magnifying window
Product Overview
- Unique one-button operation offers fast and ergonomic handling
- Spring loaded tip cone improves user to user reproducibility and ergonomics
- Secondary adjustment to adjust pipette to a liquid very different than water
- Quick connect lower part enables easy cleaning and maintenance of your pipette
- Outstanding precision and accuracy
- External edges made from stainless steel equip the pipette with outstanding robustness
- Embedded RFID chip contains all relevant data regarding the pipette
- 9 digit volume display with magnifying window
Product Overview
- Unique one-button operation offers fast and ergonomic handling
- Spring loaded tip cone improves user to user reproducibility and ergonomics
- Secondary adjustment to adjust pipette to a liquid very different than water
- Quick connect lower part enables easy cleaning and maintenance of your pipette
- Outstanding precision and accuracy
- External edges made from stainless steel equip the pipette with outstanding robustness
- Embedded RFID chip contains all relevant data regarding the pipette
- 7 digit volume display with magnifying window
Product Overview
- Unique one-button operation offers fast and ergonomic handling
- Spring loaded tip cone improves user to user reproducibility and ergonomics
- Secondary adjustment to adjust pipette to a liquid very different than water
- Quick connect lower part enables easy cleaning and maintenance of your pipette
- Outstanding precision and accuracy
- External edges made from stainless steel equip the pipette with outstanding robustness
- Embedded RFID chip contains all relevant data regarding the pipette
- 4 digit volume display with magnifying window
Product Overview
- Unique one-button operation offers fast and ergonomic handling
- Spring loaded tip cone improves user to user reproducibility and ergonomics
- Secondary adjustment to adjust pipette to a liquid very different than water
- Quick connect lower part enables easy cleaning and maintenance of your pipette
- Outstanding precision and accuracy
- External edges made from stainless steel equip the pipette with outstanding robustness
- Embedded RFID chip contains all relevant data regarding the pipette
- 5 digit volume display with magnifying window
Product Overview
- Unique one-button operation offers fast and ergonomic handling
- Spring loaded tip cone improves user to user reproducibility and ergonomics
- Secondary adjustment to adjust pipette to a liquid very different than water
- Quick connect lower part enables easy cleaning and maintenance of your pipette
- Outstanding precision and accuracy
- External edges made from stainless steel equip the pipette with outstanding robustness
- Embedded RFID chip contains all relevant data regarding the pipette
- 8 digit volume display with magnifying window
Product Overview
- Unique one-button operation offers fast and ergonomic handling
- Spring loaded tip cone improves user to user reproducibility and ergonomics
- Secondary adjustment to adjust pipette to a liquid very different than water
- Quick connect lower part enables easy cleaning and maintenance of your pipette
- Outstanding precision and accuracy
- External edges made from stainless steel equip the pipette with outstanding robustness
- Embedded RFID chip contains all relevant data regarding the pipette
- 14 digit volume display with magnifying window
Product Overview
- Unique one-button operation offers fast and ergonomic handling
- Spring loaded tip cone improves user to user reproducibility and ergonomics
- Secondary adjustment to adjust pipette to a liquid very different than water
- Quick connect lower part enables easy cleaning and maintenance of your pipette
- Outstanding precision and accuracy
- External edges made from stainless steel equip the pipette with outstanding robustness
- Embedded RFID chip contains all relevant data regarding the pipette
- 6 digit volume display with magnifying window
Product Overview
- Unique one-button operation offers fast and ergonomic handling
- Spring loaded tip cone improves user to user reproducibility and ergonomics
- Secondary adjustment to adjust pipette to a liquid very different than water
- Quick connect lower part enables easy cleaning and maintenance of your pipette
- Outstanding precision and accuracy
- External edges made from stainless steel equip the pipette with outstanding robustness
- Embedded RFID chip contains all relevant data regarding the pipette
- 12 digit volume display with magnifying window
Product Overview
- Unique one-button operation offers fast and ergonomic handling
- Spring loaded tip cone improves user to user reproducibility and ergonomics
- Secondary adjustment to adjust pipette to a liquid very different than water
- Quick connect lower part enables easy cleaning and maintenance of your pipette
- Outstanding precision and accuracy
- External edges made from stainless steel equip the pipette with outstanding robustness
- Embedded RFID chip contains all relevant data regarding the pipette
- 20 digit volume display with magnifying window
Product Overview
- Unique one-button operation offers fast and ergonomic handling
- Spring loaded tip cone improves user to user reproducibility and ergonomics
- Secondary adjustment to adjust pipette to a liquid very different than water
- Quick connect lower part enables easy cleaning and maintenance of your pipette
- Outstanding precision and accuracy
- External edges made from stainless steel equip the pipette with outstanding robustness
- Embedded RFID chip contains all relevant data regarding the pipette
- 15 digit volume display with magnifying window
Technical Specifications
Product Type | Pipettes |
Pipetting Type | Air-cushion system |
Number Of Channels | 1-channel |
Volume Range | 30 – 300 μL |
Color Code | orange |
Volume Increment | 0.2 μL |
Operating Mode | mechanical |
Spring-loaded Tip Cone | yes |
Random Measurement Error | 15 μL: ± 1.4%; ± 0.21 μL30 μL: ± 0.7%; ± 0.21 μL150 μL: ± 0.3%; ± 0.45 μL300 μL: ± 0.2%; ± 0.6 μL |
Systematic Measurement Error | 15 μL: ± 5%; ± 0.75 μL30 μL: ± 2.5%; ± 0.75 μL150 μL: ± 1%; ± 1.5 μL300 μL: ± 0.6%; ± 1.8 μL |
Autoclavable | yes |
Consumables | epT.I.P.S.® |
Open System (third Party Consumables) | yes |
Delivery Content | Pipette, epT.I.P.S.® Box 2.0 pipette tips, Operating manual, Certificate, Adjustment seal for temporary adjustment, Adjustment seal for factory adjustment (x2), Grease for pipettes, Locking ring (to prevent spring action) |
Technical Specifications
Product Type | Pipettes |
Pipetting Type | Air-cushion system |
Number Of Channels | 8-channel |
Volume Range | 30 – 300 μL |
Color Code | orange |
Volume Increment | 0.2 μL |
Operating Mode | mechanical |
Spring-loaded Tip Cone | yes |
Random Measurement Error | 15 μL: ± 2%; ± 0.3 μL30 μL: ± 1%; ± 0.3 μL150 μL: ± 0.5%; ± 0.75 μL300 μL: ± 0.3%; ± 0.9 μL |
Systematic Measurement Error | 15 μL: ± 6%; ± 0.9 μL30 μL: ± 3%; ± 0.9 μL150 μL: ± 1%; ± 1.5 μL300 μL: ± 0.6%; ± 1.8 μL |
Autoclavable | yes |
Consumables | epT.I.P.S.® |
Open System (third Party Consumables) | yes |
Delivery Content | Pipette, Operating manual, Certificate, Adjustment seal for temporary adjustment, Adjustment seal for factory adjustment (x2), Grease for pipettes, O-ring tool |
Technical Specifications
Product Type | Pipettes |
Pipetting Type | Air-cushion system |
Number Of Channels | 12-channel |
Volume Range | 10 – 100 μL |
Color Code | yellow |
Volume Increment | 0.1 μL |
Operating Mode | mechanical |
Spring-loaded Tip Cone | yes |
Random Measurement Error | 5 μL: ± 4%; ± 0.2 μL10 μL: ± 2%; ± 0.2 μL50 μL: ± 0.8%; ± 0.4 μL100 μL: ± 0.3%; ± 0.3 μL |
Systematic Measurement Error | 5 μL: ± 6%; ± 0.3 μL10 μL: ± 3%; ± 0.3 μL50 μL: ± 1%; ± 0.5 μL100 μL: ± 0.8%; ± 0.8 μL |
Autoclavable | yes |
Consumables | epT.I.P.S.® |
Open System (third Party Consumables) | yes |
Delivery Content | Pipette, Operating manual, Certificate, Adjustment seal for temporary adjustment, Adjustment seal for factory adjustment (x2), Grease for pipettes, O-ring tool |
Technical Specifications
Product Type | Pipettes |
Pipetting Type | Air-cushion system |
Number Of Channels | 8-channel |
Volume Range | 10 – 100 μL |
Color Code | yellow |
Volume Increment | 0.1 μL |
Operating Mode | mechanical |
Spring-loaded Tip Cone | yes |
Random Measurement Error | 5 μL: ± 4%; ± 0.2 μL10 μL: ± 2%; ± 0.2 μL50 μL: ± 0.8%; ± 0.4 μL100 μL: ± 0.3%; ± 0.3 μL |
Systematic Measurement Error | 5 μL: ± 6%; ± 0.3 μL10 μL: ± 3%; ± 0.3 μL50 μL: ± 1%; ± 0.5 μL100 μL: ± 0.8%; ± 0.8 μL |
Autoclavable | yes |
Consumables | epT.I.P.S.® |
Open System (third Party Consumables) | yes |
Delivery Content | Pipette, Operating manual, Certificate, Adjustment seal for temporary adjustment, Adjustment seal for factory adjustment (x2), Grease for pipettes, O-ring tool |
Technical Specifications
Product Type | Pipettes |
Pipetting Type | Air-cushion system |
Number Of Channels | 1-channel |
Volume Range | 100 – 1,000 μL |
Color Code | blue |
Volume Increment | 1 μL |
Operating Mode | mechanical |
Spring-loaded Tip Cone | yes |
Random Measurement Error | 50 μL: ± 1.2%; ± 0.6 μL100 μL: ± 0.6%; ± 0.6 μL500 μL: ± 0.2%; ± 1 μL1.000 μL: ± 0.2%; ± 2 μL |
Systematic Measurement Error | 50 μL: ± 6%; ± 3 μL100 μL: ± 3%; ± 3 μL500 μL: ± 1%; ± 5 μL1.000 μL: ± 0.6%; ± 6 μL |
Autoclavable | yes |
Consumables | epT.I.P.S.® |
Open System (third Party Consumables) | yes |
Delivery Content | Pipette, epT.I.P.S.® Box 2.0 pipette tips, Operating manual, Certificate, Adjustment seal for temporary adjustment, Adjustment seal for factory adjustment (x2), Grease for pipettes, Locking ring (to prevent spring action) |
Technical Specifications
Product Type | Pipettes |
Pipetting Type | Air-cushion system |
Number Of Channels | 1-channel |
Volume Range | 0.5 – 5 mL |
Color Code | violet |
Volume Increment | 0.005 mL |
Operating Mode | mechanical |
Spring-loaded Tip Cone | no |
Random Measurement Error | 250 μL: ± 1.2%; ± 3 μL500 μL: ± 0.6%; ± 3 μL2500 μL: ± 0.25%; ± 6.25 μL5.000 μL: ± 0.15%; ± 7.5 μL |
Systematic Measurement Error | 250 μL: ± 4.8%; ± 12 μL500 μL: ± 2.4%; ± 12 μL2500 μL: ± 1.2%; ± 30 μL5.000 μL: ± 0.6%; ± 30 μL |
Autoclavable | yes |
Consumables | epT.I.P.S.® |
Open System (third Party Consumables) | yes |
Delivery Content | Pipette, epT.I.P.S.® pipette tips sample bag, Operating manual, Certificate, Adjustment seal for temporary adjustment, Adjustment seal for factory adjustment (x2), Grease for pipettes, Filter sleeve, Filter cartridges (x10), Pipette wrench |
Technical Specifications
Product Type | Pipettes |
Pipetting Type | Air-cushion system |
Number Of Channels | 12-channel |
Volume Range | 0.5 – 10 μL |
Color Code | medium gray |
Volume Increment | 0.01 μL |
Operating Mode | mechanical |
Spring-loaded Tip Cone | yes |
Random Measurement Error | 0.5 μL: ± 8%; ± 0.04 μL1 μL: ± 5%; ± 0.05 μL5 μL: ± 2%; ± 0.1 μL10 μL: ± 1%; ± 0.1 μL |
Systematic Measurement Error | 0.5 μL: ± 12%; ± 0.06 μL1 μL: ± 8%; ± 0.08 μL5 μL: ± 4%; ± 0.2 μL10 μL: ± 2%; ± 0.2 μL |
Autoclavable | yes |
Consumables | epT.I.P.S.® |
Open System (third Party Consumables) | yes |
Delivery Content | Pipette, Operating manual, Certificate, Adjustment seal for temporary adjustment, Adjustment seal for factory adjustment (x2), Grease for pipettes |
Technical Specifications
Product Type | Pipettes |
Pipetting Type | Air-cushion system |
Number Of Channels | 1-channel |
Volume Range | 20 – 200 μL |
Color Code | yellow |
Volume Increment | 0.2 μL |
Operating Mode | mechanical |
Spring-loaded Tip Cone | yes |
Random Measurement Error | 10 μL: ± 1.4%; ± 0.14 μL20 μL: ± 0.7%; ± 0.14 μL100 μL: ± 0.3%; ± 0.03 μL200 μL: ± 0.2%; ± 0.4 μL |
Systematic Measurement Error | 10 μL: ± 5%; ± 0.5 μL20 μL: ± 2.5%; ± 0.5 μL100 μL: ± 1%; ± 1 μL200 μL: ± 0.6%; ± 1.2 μL |
Autoclavable | yes |
Consumables | epT.I.P.S.® |
Open System (third Party Consumables) | yes |
Delivery Content | Pipette, epT.I.P.S.® Box 2.0 pipette tips, Operating manual, Certificate, Adjustment seal for temporary adjustment, Adjustment seal for factory adjustment (x2), Grease for pipettes, Locking ring (to prevent spring action) |
Technical Specifications
Product Type | Pipettes |
Pipetting Type | Air-cushion system |
Number Of Channels | 1-channel |
Volume Range | 2 – 20 μL |
Color Code | yellow |
Volume Increment | 0.02 μL |
Operating Mode | mechanical |
Spring-loaded Tip Cone | yes |
Random Measurement Error | 1 μL: ± 3%; ± 0.03 μL2 μL: ± 1.5%; ± 0.03 μL20 μL: ± 0.6%; ± 0.06 μL20 μL: ± 0.3%; ± 0.06 μL |
Systematic Measurement Error | 1 μL: ± 10%; ± 0.1 μL2 μL: ± 5%; ± 0.1 μL20 μL: ± 1.2%; ± 0.12 μL20 μL: ± 1%; ± 0.2 μL |
Autoclavable | yes |
Consumables | epT.I.P.S.® |
Open System (third Party Consumables) | yes |
Delivery Content | Pipette, epT.I.P.S.® Box 2.0 pipette tips, Operating manual, Certificate, Adjustment seal for temporary adjustment, Adjustment seal for factory adjustment (x2), Grease for pipettes, Locking ring (to prevent spring action) |
Technical Specifications
Product Type | Pipettes |
Pipetting Type | Air-cushion system |
Number Of Channels | 1-channel |
Volume Range | 0.1 – 2.5 μL |
Color Code | dark gray |
Volume Increment | 0.002 μL |
Operating Mode | mechanical |
Spring-loaded Tip Cone | yes |
Random Measurement Error | 0.1 μL: ± 12%; ± 0.012 μL0.25 μL: ± 6%; ± 0.015 μL1.25 μL: ± 1.5%; ± 0.01875 μL2.5 μL: ± 0.7%; ± 0.0175 μL |
Systematic Measurement Error | 0.1 μL: ± 48%; ± 0.048 μL0.25 μL: ± 12%; ± 0.03 μL1.25 μL: ± 2.5%; ± 0.031 μL2.5 μL: ± 1.4%; ± 0.035 μL |
Autoclavable | yes |
Consumables | epT.I.P.S.® |
Open System (third Party Consumables) | yes |
Delivery Content | Pipette, epT.I.P.S.® Box 2.0 pipette tips, Operating manual, Certificate, Adjustment seal for temporary adjustment, Adjustment seal for factory adjustment (x2), Grease for pipettes, Locking ring (to prevent spring action) |
Technical Specifications
Product Type | Pipettes |
Pipetting Type | Air-cushion system |
Number Of Channels | 1-channel |
Volume Range | 0.5 – 10 μL |
Color Code | medium gray |
Volume Increment | 0.01 μL |
Operating Mode | mechanical |
Spring-loaded Tip Cone | yes |
Random Measurement Error | 0.5 μL: ± 5%; ± 0.025 μL1 μL: ± 1.8%; ± 0.018 μL5 μL: ± 0.8%; ± 0.04 μL10 μL: ± 0.4%; ± 0.04 μL |
Systematic Measurement Error | 0.5 μL: ± 8%; ± 0.04 μL1 μL: ± 2.5%; ± 0.025 μL5 μL: ± 1.5%; ± 0.075 μL10 μL: ± 1%; ± 0.1 μL |
Autoclavable | yes |
Consumables | epT.I.P.S.® |
Open System (third Party Consumables) | yes |
Delivery Content | Pipette, epT.I.P.S.® Box 2.0 pipette tips, Operating manual, Certificate, Adjustment seal for temporary adjustment, Adjustment seal for factory adjustment (x2), Grease for pipettes, Locking ring (to prevent spring action) |
Technical Specifications
Product Type | Pipettes |
Pipetting Type | Air-cushion system |
Number Of Channels | 1-channel |
Volume Range | 10 – 100 μL |
Color Code | yellow |
Volume Increment | 0.1 μL |
Operating Mode | mechanical |
Spring-loaded Tip Cone | yes |
Random Measurement Error | 5 μL: ± 2%; ± 0.1 μL10 μL: ± 0.7%; ± 0.7 μL50 μL: ± 0.3%; ± 0.015 μL100 μL: ± 0.2%; ± 0.02 μL |
Systematic Measurement Error | 5 μL: ± 6%; ± 0.3 μL10 μL: ± 3%; ± 0.3 μL50 μL: ± 1%; ± 0.5 μL100 μL: ± 0.8%; ± 0.8 μL |
Autoclavable | yes |
Consumables | epT.I.P.S.® |
Open System (third Party Consumables) | yes |
Delivery Content | Pipette, epT.I.P.S.® Box 2.0 pipette tips, Operating manual, Certificate, Adjustment seal for temporary adjustment, Adjustment seal for factory adjustment (x2), Grease for pipettes, Locking ring (to prevent spring action) |
Technical Specifications
Product Type | Pipettes |
Pipetting Type | Air-cushion system |
Number Of Channels | 1-channel |
Volume Range | 1 – 10 mL |
Color Code | turquoise |
Volume Increment | 0.01 mL |
Operating Mode | mechanical |
Spring-loaded Tip Cone | no |
Random Measurement Error | 500 μL: ± 1.2%; ± 6 μL1.000 μL: ± 0.6%; ± 6 μL5.000 μL: ± 0.2%; ± 10 μL10.000 μL: ± 0.15%; ± 15 μL |
Systematic Measurement Error | 500 μL: ± 6%; ± 30 μL1.000 μL: ± 3%; ± 30 μL5.000 μL: ± 0.8%; ± 40 μL10.000 μL: ± 0.6%; ± 60 μL |
Autoclavable | yes |
Consumables | epT.I.P.S.® |
Open System (third Party Consumables) | yes |
Delivery Content | Pipette, epT.I.P.S.® pipette tips sample bag, Operating manual, Certificate, Adjustment seal for temporary adjustment, Adjustment seal for factory adjustment (x2), Grease for pipettes, Filter sleeve, Filter cartridges (x10), Pipette wrench |
Technical Specifications
Product Type | Pipettes |
Pipetting Type | Air-cushion system |
Number Of Channels | 1-channel |
Volume Range | 2 – 20 μL |
Color Code | light gray |
Volume Increment | 0.02 μL |
Operating Mode | mechanical |
Spring-loaded Tip Cone | yes |
Random Measurement Error | 1 μL: ± 3%; ± 0.03 μL2 μL: ± 1.5%; ± 0.03 μL20 μL: ± 0.6%; ± 0.06 μL20 μL: ± 0.3%; ± 0.06 μL |
Systematic Measurement Error | 1 μL: ± 10%; ± 0.1 μL2 μL: ± 3%; ± 0.06 μL20 μL: ± 1%; ± 0.1 μL20 μL: ± 0.8%; ± 0.16 μL |
Autoclavable | yes |
Consumables | epT.I.P.S.® |
Open System (third Party Consumables) | yes |
Delivery Content | Pipette, epT.I.P.S.® Box 2.0 pipette tips, Operating manual, Certificate, Adjustment seal for temporary adjustment, Adjustment seal for factory adjustment (x2), Grease for pipettes, Locking ring (to prevent spring action) |
Technical Specifications
Product Type | Pipettes |
Pipetting Type | Air-cushion system |
Number Of Channels | 1-channel |
Volume Range | 0.25 – 2.5 mL |
Color Code | red |
Volume Increment | 0.002 mL |
Operating Mode | mechanical |
Spring-loaded Tip Cone | no |
Random Measurement Error | 250 μL: ± 1.2%; ± 3 μL500 μL: ± 0.3%; ± 1.5 μL1250 μL: ± 0.2%; ± 2.5 μL2500 μL: ± 0.2%; ± 5 μL |
Systematic Measurement Error | 250 μL: ± 4.8%; ± 1.2 μL500 μL: ± 1.5%; ± 7.5 μL1250 μL: ± 0.8%; ± 10 μL2500 μL: ± 0.6%; ± 15 μL |
Autoclavable | yes |
Consumables | epT.I.P.S.® |
Open System (third Party Consumables) | yes |
Delivery Content | Pipette, epT.I.P.S.® pipette tips sample bag, Operating manual, Certificate, Adjustment seal for temporary adjustment, Adjustment seal for factory adjustment (x2), Grease for pipettes, Filter sleeve, Filter cartridges (x10), Pipette wrench |
Technical Specifications
Product Type | Pipettes |
Pipetting Type | Air-cushion system |
Number Of Channels | 12-channel |
Volume Range | 30 – 300 μL |
Color Code | orange |
Volume Increment | 0.2 μL |
Operating Mode | mechanical |
Spring-loaded Tip Cone | yes |
Random Measurement Error | 15 μL: ± 2%; ± 0.3 μL30 μL: ± 1%; ± 0.3 μL150 μL: ± 0.5%; ± 0.75 μL300 μL: ± 0.3%; ± 0.9 μL |
Systematic Measurement Error | 15 μL: ± 6%; ± 0.9 μL30 μL: ± 3%; ± 0.9 μL150 μL: ± 1%; ± 1.5 μL300 μL: ± 0.6%; ± 1.8 μL |
Autoclavable | yes |
Consumables | epT.I.P.S.® |
Open System (third Party Consumables) | yes |
Delivery Content | Pipette, Operating manual, Certificate, Adjustment seal for temporary adjustment, Adjustment seal for factory adjustment (x2), Grease for pipettes, O-ring tool |
Technical Specifications
Product Type | Pipettes |
Pipetting Type | Air-cushion system |
Number Of Channels | 8-channel |
Volume Range | 0.5 – 10 μL |
Color Code | medium gray |
Volume Increment | 0.01 μL |
Operating Mode | mechanical |
Spring-loaded Tip Cone | yes |
Random Measurement Error | 0.5 μL: ± 8%; ± 0.04 μL1 μL: ± 5%; ± 0.05 μL5 μL: ± 2%; ± 0.1 μL10 μL: ± 1%; ± 0.1 μL |
Systematic Measurement Error | 0.5 μL: ± 12%; ± 0.06 μL1 μL: ± 8%; ± 0.08 μL5 μL: ± 4%; ± 0.2 μL10 μL: ± 2%; ± 0.2 μL |
Autoclavable | yes |
Consumables | epT.I.P.S.® |
Open System (third Party Consumables) | yes |
Delivery Content | Pipette, Operating manual, Certificate, Adjustment seal for temporary adjustment, Adjustment seal for factory adjustment (x2), Grease for pipettes |
Technical Documents
- Calibration Done Right
- Get It Right! Selection Chart for Liquid Handling Instruments & Tips
- Increase Your Pipetting Productivity Today
- Natural Winners
- Pipette Service
- Pipette Service Done Right
- Grease for Pipettes
- Change Filter
- Combination of epT.I.P.S.® Pipette Tips with Eppendorf Pipettes
- Eppendorf Reference® 2
- Eppendorf Reference® 2
- Eppendorf Reference® 2
- Eppendorf Reference® 2
- Grease for Pipettes
- Pipette Service Form
- Standard operating procedure for manual dispensing systems
- 019 – Fundamentals of Dispensing
- 020 – Impact of Pipetting Techniques on Precision and Accuracy
- 021 – Influence of physical parameters on the dispensed volume of air-cushion pipette
- 024 – Cleaning and Inspection of Pipettes
- 025 – Calibration and Adjustment of Dispensing Systems in the Laboratory
- 035 – Five Challenges in Plate Assays that Can Be Mastered by the Right Choice of Pipetting Tool
- 046 – The Eppendorf PhysioCare Concept® - 3 Spheres Model
- 082 – What Really Matters
- 085 – Requirements and Eppendorf Solutions for Immunological Analyses
- 198 – The Eppendorf Mechanical Pipettes Research® plus and Reference® 2 – Fully Autoclavable, Easy Adjustment, Quick and Simple Maintenance
- 354 – The Tip of the Iceberg: How Pipette Tips Influence Results
- Maintenance of Reference 2
- Pipetting Techniques
- Transferring Non-Aqueous Liquids
Technical Documents
- Calibration Done Right
- Get It Right! Selection Chart for Liquid Handling Instruments & Tips
- Increase Your Pipetting Productivity Today
- Natural Winners
- Pipette Service
- Pipette Service Done Right
- Grease for Pipettes
- Change Filter
- Combination of epT.I.P.S.® Pipette Tips with Eppendorf Pipettes
- Eppendorf Reference® 2
- Eppendorf Reference® 2
- Eppendorf Reference® 2
- Eppendorf Reference® 2
- Grease for Pipettes
- Pipette Service Form
- Standard operating procedure for manual dispensing systems
- 019 – Fundamentals of Dispensing
- 020 – Impact of Pipetting Techniques on Precision and Accuracy
- 021 – Influence of physical parameters on the dispensed volume of air-cushion pipette
- 024 – Cleaning and Inspection of Pipettes
- 025 – Calibration and Adjustment of Dispensing Systems in the Laboratory
- 035 – Five Challenges in Plate Assays that Can Be Mastered by the Right Choice of Pipetting Tool
- 046 – The Eppendorf PhysioCare Concept® - 3 Spheres Model
- 082 – What Really Matters
- 085 – Requirements and Eppendorf Solutions for Immunological Analyses
- 198 – The Eppendorf Mechanical Pipettes Research® plus and Reference® 2 – Fully Autoclavable, Easy Adjustment, Quick and Simple Maintenance
- 354 – The Tip of the Iceberg: How Pipette Tips Influence Results
- Maintenance of Reference 2
- Pipetting Techniques
- Transferring Non-Aqueous Liquids
Technical Documents
- Calibration Done Right
- Get It Right! Selection Chart for Liquid Handling Instruments & Tips
- Increase Your Pipetting Productivity Today
- Natural Winners
- Pipette Service
- Pipette Service Done Right
- Grease for Pipettes
- Change Filter
- Combination of epT.I.P.S.® Pipette Tips with Eppendorf Pipettes
- Eppendorf Reference® 2
- Eppendorf Reference® 2
- Eppendorf Reference® 2
- Eppendorf Reference® 2
- Grease for Pipettes
- Pipette Service Form
- Standard operating procedure for manual dispensing systems
- 019 – Fundamentals of Dispensing
- 020 – Impact of Pipetting Techniques on Precision and Accuracy
- 021 – Influence of physical parameters on the dispensed volume of air-cushion pipette
- 024 – Cleaning and Inspection of Pipettes
- 025 – Calibration and Adjustment of Dispensing Systems in the Laboratory
- 035 – Five Challenges in Plate Assays that Can Be Mastered by the Right Choice of Pipetting Tool
- 046 – The Eppendorf PhysioCare Concept® - 3 Spheres Model
- 082 – What Really Matters
- 085 – Requirements and Eppendorf Solutions for Immunological Analyses
- 198 – The Eppendorf Mechanical Pipettes Research® plus and Reference® 2 – Fully Autoclavable, Easy Adjustment, Quick and Simple Maintenance
- 354 – The Tip of the Iceberg: How Pipette Tips Influence Results
- Maintenance of Reference 2
- Pipetting Techniques
- Transferring Non-Aqueous Liquids
Technical Documents
- Calibration Done Right
- Get It Right! Selection Chart for Liquid Handling Instruments & Tips
- Increase Your Pipetting Productivity Today
- Natural Winners
- Pipette Service
- Pipette Service Done Right
- Grease for Pipettes
- Change Filter
- Combination of epT.I.P.S.® Pipette Tips with Eppendorf Pipettes
- Eppendorf Reference® 2
- Eppendorf Reference® 2
- Eppendorf Reference® 2
- Eppendorf Reference® 2
- Grease for Pipettes
- Pipette Service Form
- Standard operating procedure for manual dispensing systems
- 019 – Fundamentals of Dispensing
- 020 – Impact of Pipetting Techniques on Precision and Accuracy
- 021 – Influence of physical parameters on the dispensed volume of air-cushion pipette
- 024 – Cleaning and Inspection of Pipettes
- 025 – Calibration and Adjustment of Dispensing Systems in the Laboratory
- 035 – Five Challenges in Plate Assays that Can Be Mastered by the Right Choice of Pipetting Tool
- 046 – The Eppendorf PhysioCare Concept® - 3 Spheres Model
- 082 – What Really Matters
- 085 – Requirements and Eppendorf Solutions for Immunological Analyses
- 198 – The Eppendorf Mechanical Pipettes Research® plus and Reference® 2 – Fully Autoclavable, Easy Adjustment, Quick and Simple Maintenance
- 354 – The Tip of the Iceberg: How Pipette Tips Influence Results
- Maintenance of Reference 2
- Pipetting Techniques
- Transferring Non-Aqueous Liquids
Technical Documents
- Calibration Done Right
- Get It Right! Selection Chart for Liquid Handling Instruments & Tips
- Increase Your Pipetting Productivity Today
- Natural Winners
- Pipette Service
- Pipette Service Done Right
- Grease for Pipettes
- Change Filter
- Combination of epT.I.P.S.® Pipette Tips with Eppendorf Pipettes
- Eppendorf Reference® 2
- Eppendorf Reference® 2
- Eppendorf Reference® 2
- Eppendorf Reference® 2
- Grease for Pipettes
- Pipette Service Form
- Standard operating procedure for manual dispensing systems
- 019 – Fundamentals of Dispensing
- 020 – Impact of Pipetting Techniques on Precision and Accuracy
- 021 – Influence of physical parameters on the dispensed volume of air-cushion pipette
- 024 – Cleaning and Inspection of Pipettes
- 025 – Calibration and Adjustment of Dispensing Systems in the Laboratory
- 035 – Five Challenges in Plate Assays that Can Be Mastered by the Right Choice of Pipetting Tool
- 046 – The Eppendorf PhysioCare Concept® - 3 Spheres Model
- 082 – What Really Matters
- 085 – Requirements and Eppendorf Solutions for Immunological Analyses
- 198 – The Eppendorf Mechanical Pipettes Research® plus and Reference® 2 – Fully Autoclavable, Easy Adjustment, Quick and Simple Maintenance
- 354 – The Tip of the Iceberg: How Pipette Tips Influence Results
- Maintenance of Reference 2
- Pipetting Techniques
- Transferring Non-Aqueous Liquids
Technical Documents
- Calibration Done Right
- Get It Right! Selection Chart for Liquid Handling Instruments & Tips
- Increase Your Pipetting Productivity Today
- Natural Winners
- Pipette Service
- Pipette Service Done Right
- Grease for Pipettes
- Change Filter
- Combination of epT.I.P.S.® Pipette Tips with Eppendorf Pipettes
- Eppendorf Reference® 2
- Eppendorf Reference® 2
- Eppendorf Reference® 2
- Eppendorf Reference® 2
- Grease for Pipettes
- Pipette Service Form
- Standard operating procedure for manual dispensing systems
- 019 – Fundamentals of Dispensing
- 020 – Impact of Pipetting Techniques on Precision and Accuracy
- 021 – Influence of physical parameters on the dispensed volume of air-cushion pipette
- 024 – Cleaning and Inspection of Pipettes
- 025 – Calibration and Adjustment of Dispensing Systems in the Laboratory
- 035 – Five Challenges in Plate Assays that Can Be Mastered by the Right Choice of Pipetting Tool
- 046 – The Eppendorf PhysioCare Concept® - 3 Spheres Model
- 082 – What Really Matters
- 085 – Requirements and Eppendorf Solutions for Immunological Analyses
- 198 – The Eppendorf Mechanical Pipettes Research® plus and Reference® 2 – Fully Autoclavable, Easy Adjustment, Quick and Simple Maintenance
- 354 – The Tip of the Iceberg: How Pipette Tips Influence Results
- Maintenance of Reference 2
- Pipetting Techniques
- Transferring Non-Aqueous Liquids
Technical Documents
- Calibration Done Right
- Get It Right! Selection Chart for Liquid Handling Instruments & Tips
- Increase Your Pipetting Productivity Today
- Natural Winners
- Pipette Service
- Pipette Service Done Right
- Grease for Pipettes
- Change Filter
- Combination of epT.I.P.S.® Pipette Tips with Eppendorf Pipettes
- Eppendorf Reference® 2
- Eppendorf Reference® 2
- Eppendorf Reference® 2
- Eppendorf Reference® 2
- Grease for Pipettes
- Pipette Service Form
- Standard operating procedure for manual dispensing systems
- 019 – Fundamentals of Dispensing
- 020 – Impact of Pipetting Techniques on Precision and Accuracy
- 021 – Influence of physical parameters on the dispensed volume of air-cushion pipette
- 024 – Cleaning and Inspection of Pipettes
- 025 – Calibration and Adjustment of Dispensing Systems in the Laboratory
- 035 – Five Challenges in Plate Assays that Can Be Mastered by the Right Choice of Pipetting Tool
- 046 – The Eppendorf PhysioCare Concept® - 3 Spheres Model
- 082 – What Really Matters
- 085 – Requirements and Eppendorf Solutions for Immunological Analyses
- 198 – The Eppendorf Mechanical Pipettes Research® plus and Reference® 2 – Fully Autoclavable, Easy Adjustment, Quick and Simple Maintenance
- 354 – The Tip of the Iceberg: How Pipette Tips Influence Results
- Maintenance of Reference 2
- Pipetting Techniques
- Transferring Non-Aqueous Liquids
Technical Documents
- Calibration Done Right
- Get It Right! Selection Chart for Liquid Handling Instruments & Tips
- Increase Your Pipetting Productivity Today
- Natural Winners
- Pipette Service
- Pipette Service Done Right
- Grease for Pipettes
- Change Filter
- Combination of epT.I.P.S.® Pipette Tips with Eppendorf Pipettes
- Eppendorf Reference® 2
- Eppendorf Reference® 2
- Eppendorf Reference® 2
- Eppendorf Reference® 2
- Grease for Pipettes
- Pipette Service Form
- Standard operating procedure for manual dispensing systems
- 019 – Fundamentals of Dispensing
- 020 – Impact of Pipetting Techniques on Precision and Accuracy
- 021 – Influence of physical parameters on the dispensed volume of air-cushion pipette
- 024 – Cleaning and Inspection of Pipettes
- 025 – Calibration and Adjustment of Dispensing Systems in the Laboratory
- 035 – Five Challenges in Plate Assays that Can Be Mastered by the Right Choice of Pipetting Tool
- 046 – The Eppendorf PhysioCare Concept® - 3 Spheres Model
- 082 – What Really Matters
- 085 – Requirements and Eppendorf Solutions for Immunological Analyses
- 198 – The Eppendorf Mechanical Pipettes Research® plus and Reference® 2 – Fully Autoclavable, Easy Adjustment, Quick and Simple Maintenance
- 354 – The Tip of the Iceberg: How Pipette Tips Influence Results
- Maintenance of Reference 2
- Pipetting Techniques
- Transferring Non-Aqueous Liquids
Technical Documents
- Calibration Done Right
- Get It Right! Selection Chart for Liquid Handling Instruments & Tips
- Increase Your Pipetting Productivity Today
- Natural Winners
- Pipette Service
- Pipette Service Done Right
- Grease for Pipettes
- Change Filter
- Combination of epT.I.P.S.® Pipette Tips with Eppendorf Pipettes
- Eppendorf Reference® 2
- Eppendorf Reference® 2
- Eppendorf Reference® 2
- Eppendorf Reference® 2
- Grease for Pipettes
- Pipette Service Form
- Standard operating procedure for manual dispensing systems
- 019 – Fundamentals of Dispensing
- 020 – Impact of Pipetting Techniques on Precision and Accuracy
- 021 – Influence of physical parameters on the dispensed volume of air-cushion pipette
- 024 – Cleaning and Inspection of Pipettes
- 025 – Calibration and Adjustment of Dispensing Systems in the Laboratory
- 035 – Five Challenges in Plate Assays that Can Be Mastered by the Right Choice of Pipetting Tool
- 046 – The Eppendorf PhysioCare Concept® - 3 Spheres Model
- 082 – What Really Matters
- 085 – Requirements and Eppendorf Solutions for Immunological Analyses
- 198 – The Eppendorf Mechanical Pipettes Research® plus and Reference® 2 – Fully Autoclavable, Easy Adjustment, Quick and Simple Maintenance
- 354 – The Tip of the Iceberg: How Pipette Tips Influence Results
- Maintenance of Reference 2
- Pipetting Techniques
- Transferring Non-Aqueous Liquids
Technical Documents
- Calibration Done Right
- Get It Right! Selection Chart for Liquid Handling Instruments & Tips
- Increase Your Pipetting Productivity Today
- Natural Winners
- Pipette Service
- Pipette Service Done Right
- Grease for Pipettes
- Change Filter
- Combination of epT.I.P.S.® Pipette Tips with Eppendorf Pipettes
- Eppendorf Reference® 2
- Eppendorf Reference® 2
- Eppendorf Reference® 2
- Eppendorf Reference® 2
- Grease for Pipettes
- Pipette Service Form
- Standard operating procedure for manual dispensing systems
- 019 – Fundamentals of Dispensing
- 020 – Impact of Pipetting Techniques on Precision and Accuracy
- 021 – Influence of physical parameters on the dispensed volume of air-cushion pipette
- 024 – Cleaning and Inspection of Pipettes
- 025 – Calibration and Adjustment of Dispensing Systems in the Laboratory
- 035 – Five Challenges in Plate Assays that Can Be Mastered by the Right Choice of Pipetting Tool
- 046 – The Eppendorf PhysioCare Concept® - 3 Spheres Model
- 082 – What Really Matters
- 085 – Requirements and Eppendorf Solutions for Immunological Analyses
- 198 – The Eppendorf Mechanical Pipettes Research® plus and Reference® 2 – Fully Autoclavable, Easy Adjustment, Quick and Simple Maintenance
- 354 – The Tip of the Iceberg: How Pipette Tips Influence Results
- Maintenance of Reference 2
- Pipetting Techniques
- Transferring Non-Aqueous Liquids
Technical Documents
- Calibration Done Right
- Get It Right! Selection Chart for Liquid Handling Instruments & Tips
- Increase Your Pipetting Productivity Today
- Natural Winners
- Pipette Service
- Pipette Service Done Right
- Grease for Pipettes
- Change Filter
- Combination of epT.I.P.S.® Pipette Tips with Eppendorf Pipettes
- Eppendorf Reference® 2
- Eppendorf Reference® 2
- Eppendorf Reference® 2
- Eppendorf Reference® 2
- Grease for Pipettes
- Pipette Service Form
- Standard operating procedure for manual dispensing systems
- 019 – Fundamentals of Dispensing
- 020 – Impact of Pipetting Techniques on Precision and Accuracy
- 021 – Influence of physical parameters on the dispensed volume of air-cushion pipette
- 024 – Cleaning and Inspection of Pipettes
- 025 – Calibration and Adjustment of Dispensing Systems in the Laboratory
- 035 – Five Challenges in Plate Assays that Can Be Mastered by the Right Choice of Pipetting Tool
- 046 – The Eppendorf PhysioCare Concept® - 3 Spheres Model
- 082 – What Really Matters
- 085 – Requirements and Eppendorf Solutions for Immunological Analyses
- 198 – The Eppendorf Mechanical Pipettes Research® plus and Reference® 2 – Fully Autoclavable, Easy Adjustment, Quick and Simple Maintenance
- 354 – The Tip of the Iceberg: How Pipette Tips Influence Results
- Maintenance of Reference 2
- Pipetting Techniques
- Transferring Non-Aqueous Liquids
Technical Documents
- Calibration Done Right
- Get It Right! Selection Chart for Liquid Handling Instruments & Tips
- Increase Your Pipetting Productivity Today
- Natural Winners
- Pipette Service
- Pipette Service Done Right
- Grease for Pipettes
- Change Filter
- Combination of epT.I.P.S.® Pipette Tips with Eppendorf Pipettes
- Eppendorf Reference® 2
- Eppendorf Reference® 2
- Eppendorf Reference® 2
- Eppendorf Reference® 2
- Grease for Pipettes
- Pipette Service Form
- Standard operating procedure for manual dispensing systems
- 019 – Fundamentals of Dispensing
- 020 – Impact of Pipetting Techniques on Precision and Accuracy
- 021 – Influence of physical parameters on the dispensed volume of air-cushion pipette
- 024 – Cleaning and Inspection of Pipettes
- 025 – Calibration and Adjustment of Dispensing Systems in the Laboratory
- 035 – Five Challenges in Plate Assays that Can Be Mastered by the Right Choice of Pipetting Tool
- 046 – The Eppendorf PhysioCare Concept® - 3 Spheres Model
- 082 – What Really Matters
- 085 – Requirements and Eppendorf Solutions for Immunological Analyses
- 198 – The Eppendorf Mechanical Pipettes Research® plus and Reference® 2 – Fully Autoclavable, Easy Adjustment, Quick and Simple Maintenance
- 354 – The Tip of the Iceberg: How Pipette Tips Influence Results
- Maintenance of Reference 2
- Pipetting Techniques
- Transferring Non-Aqueous Liquids
Technical Documents
- Calibration Done Right
- Get It Right! Selection Chart for Liquid Handling Instruments & Tips
- Increase Your Pipetting Productivity Today
- Natural Winners
- Pipette Service
- Pipette Service Done Right
- Grease for Pipettes
- Change Filter
- Combination of epT.I.P.S.® Pipette Tips with Eppendorf Pipettes
- Eppendorf Reference® 2
- Eppendorf Reference® 2
- Eppendorf Reference® 2
- Eppendorf Reference® 2
- Grease for Pipettes
- Pipette Service Form
- Standard operating procedure for manual dispensing systems
- 019 – Fundamentals of Dispensing
- 020 – Impact of Pipetting Techniques on Precision and Accuracy
- 021 – Influence of physical parameters on the dispensed volume of air-cushion pipette
- 024 – Cleaning and Inspection of Pipettes
- 025 – Calibration and Adjustment of Dispensing Systems in the Laboratory
- 035 – Five Challenges in Plate Assays that Can Be Mastered by the Right Choice of Pipetting Tool
- 046 – The Eppendorf PhysioCare Concept® - 3 Spheres Model
- 082 – What Really Matters
- 085 – Requirements and Eppendorf Solutions for Immunological Analyses
- 198 – The Eppendorf Mechanical Pipettes Research® plus and Reference® 2 – Fully Autoclavable, Easy Adjustment, Quick and Simple Maintenance
- 354 – The Tip of the Iceberg: How Pipette Tips Influence Results
- Maintenance of Reference 2
- Pipetting Techniques
- Transferring Non-Aqueous Liquids
Technical Documents
- Calibration Done Right
- Get It Right! Selection Chart for Liquid Handling Instruments & Tips
- Increase Your Pipetting Productivity Today
- Natural Winners
- Pipette Service
- Pipette Service Done Right
- Grease for Pipettes
- Change Filter
- Combination of epT.I.P.S.® Pipette Tips with Eppendorf Pipettes
- Eppendorf Reference® 2
- Eppendorf Reference® 2
- Eppendorf Reference® 2
- Eppendorf Reference® 2
- Grease for Pipettes
- Pipette Service Form
- Standard operating procedure for manual dispensing systems
- 019 – Fundamentals of Dispensing
- 020 – Impact of Pipetting Techniques on Precision and Accuracy
- 021 – Influence of physical parameters on the dispensed volume of air-cushion pipette
- 024 – Cleaning and Inspection of Pipettes
- 025 – Calibration and Adjustment of Dispensing Systems in the Laboratory
- 035 – Five Challenges in Plate Assays that Can Be Mastered by the Right Choice of Pipetting Tool
- 046 – The Eppendorf PhysioCare Concept® - 3 Spheres Model
- 082 – What Really Matters
- 085 – Requirements and Eppendorf Solutions for Immunological Analyses
- 198 – The Eppendorf Mechanical Pipettes Research® plus and Reference® 2 – Fully Autoclavable, Easy Adjustment, Quick and Simple Maintenance
- 354 – The Tip of the Iceberg: How Pipette Tips Influence Results
- Maintenance of Reference 2
- Pipetting Techniques
- Transferring Non-Aqueous Liquids
Technical Documents
- Calibration Done Right
- Get It Right! Selection Chart for Liquid Handling Instruments & Tips
- Increase Your Pipetting Productivity Today
- Natural Winners
- Pipette Service
- Pipette Service Done Right
- Grease for Pipettes
- Change Filter
- Combination of epT.I.P.S.® Pipette Tips with Eppendorf Pipettes
- Eppendorf Reference® 2
- Eppendorf Reference® 2
- Eppendorf Reference® 2
- Eppendorf Reference® 2
- Grease for Pipettes
- Pipette Service Form
- Standard operating procedure for manual dispensing systems
- 019 – Fundamentals of Dispensing
- 020 – Impact of Pipetting Techniques on Precision and Accuracy
- 021 – Influence of physical parameters on the dispensed volume of air-cushion pipette
- 024 – Cleaning and Inspection of Pipettes
- 025 – Calibration and Adjustment of Dispensing Systems in the Laboratory
- 035 – Five Challenges in Plate Assays that Can Be Mastered by the Right Choice of Pipetting Tool
- 046 – The Eppendorf PhysioCare Concept® - 3 Spheres Model
- 082 – What Really Matters
- 085 – Requirements and Eppendorf Solutions for Immunological Analyses
- 198 – The Eppendorf Mechanical Pipettes Research® plus and Reference® 2 – Fully Autoclavable, Easy Adjustment, Quick and Simple Maintenance
- 354 – The Tip of the Iceberg: How Pipette Tips Influence Results
- Maintenance of Reference 2
- Pipetting Techniques
- Transferring Non-Aqueous Liquids
Technical Documents
- Calibration Done Right
- Get It Right! Selection Chart for Liquid Handling Instruments & Tips
- Increase Your Pipetting Productivity Today
- Natural Winners
- Pipette Service
- Pipette Service Done Right
- Grease for Pipettes
- Change Filter
- Combination of epT.I.P.S.® Pipette Tips with Eppendorf Pipettes
- Eppendorf Reference® 2
- Eppendorf Reference® 2
- Eppendorf Reference® 2
- Eppendorf Reference® 2
- Grease for Pipettes
- Pipette Service Form
- Standard operating procedure for manual dispensing systems
- 019 – Fundamentals of Dispensing
- 020 – Impact of Pipetting Techniques on Precision and Accuracy
- 021 – Influence of physical parameters on the dispensed volume of air-cushion pipette
- 024 – Cleaning and Inspection of Pipettes
- 025 – Calibration and Adjustment of Dispensing Systems in the Laboratory
- 035 – Five Challenges in Plate Assays that Can Be Mastered by the Right Choice of Pipetting Tool
- 046 – The Eppendorf PhysioCare Concept® - 3 Spheres Model
- 082 – What Really Matters
- 085 – Requirements and Eppendorf Solutions for Immunological Analyses
- 198 – The Eppendorf Mechanical Pipettes Research® plus and Reference® 2 – Fully Autoclavable, Easy Adjustment, Quick and Simple Maintenance
- 354 – The Tip of the Iceberg: How Pipette Tips Influence Results
- Maintenance of Reference 2
- Pipetting Techniques
- Transferring Non-Aqueous Liquids
Technical Documents
- Calibration Done Right
- Get It Right! Selection Chart for Liquid Handling Instruments & Tips
- Increase Your Pipetting Productivity Today
- Natural Winners
- Pipette Service
- Pipette Service Done Right
- Grease for Pipettes
- Change Filter
- Combination of epT.I.P.S.® Pipette Tips with Eppendorf Pipettes
- Eppendorf Reference® 2
- Eppendorf Reference® 2
- Eppendorf Reference® 2
- Eppendorf Reference® 2
- Grease for Pipettes
- Pipette Service Form
- Standard operating procedure for manual dispensing systems
- 019 – Fundamentals of Dispensing
- 020 – Impact of Pipetting Techniques on Precision and Accuracy
- 021 – Influence of physical parameters on the dispensed volume of air-cushion pipette
- 024 – Cleaning and Inspection of Pipettes
- 025 – Calibration and Adjustment of Dispensing Systems in the Laboratory
- 035 – Five Challenges in Plate Assays that Can Be Mastered by the Right Choice of Pipetting Tool
- 046 – The Eppendorf PhysioCare Concept® - 3 Spheres Model
- 082 – What Really Matters
- 085 – Requirements and Eppendorf Solutions for Immunological Analyses
- 198 – The Eppendorf Mechanical Pipettes Research® plus and Reference® 2 – Fully Autoclavable, Easy Adjustment, Quick and Simple Maintenance
- 354 – The Tip of the Iceberg: How Pipette Tips Influence Results
- Maintenance of Reference 2
- Pipetting Techniques
- Transferring Non-Aqueous Liquids
Detailed Description
The Reference 2 is the successor to the popular Reference pipette, and enhances the pipettes already high standards with a new look, reduced weight and operating forces and multi-channel versions. As the premium product in Eppendorf’s pipette portfolio, the Reference 2 provides the most accurate results possible alongside robust, reliable handling and optimum user safety. These levels of security make the Reference 2 ideal for use with precious liquids, or in any application requiring extremely high levels of accuracy. When there can be no compromise on quality and reproducibility, Eppendorf’s new Reference 2 is an ideal instrument.
17 Product Options
Catalog Number:
86-171
List Price:
$757.6
Your Price:
$649.37
Specifications:
Volume | 30 to 300 μL |
Number of Channels | Single-Channel |
Description | For Use With 300µl Tips |
Qty/Unit | 1 Pipettor/Unit |
Catalog Number:
86-180
List Price:
$1765.01
Your Price:
$1512.86
Specifications:
Volume | 30 to 300 μL |
Number of Channels | 8-Channel |
Description | For Use With 300µl Tips |
Qty/Unit | 1 Pipettor/Unit |
Catalog Number:
86-179
List Price:
$2112.84
Your Price:
$1811
Specifications:
Volume | 10 to 100 μL |
Number of Channels | 12-Channel |
Description | For Use With 200µl Tips |
Qty/Unit | 1 Pipettor/Unit |
Catalog Number:
86-178
List Price:
$1783.36
Your Price:
$1528.6
Specifications:
Volume | 10 to 100 μL |
Number of Channels | 8-Channel |
Description | For Use With 200µl Tips |
Qty/Unit | 1 Pipettor/Unit |
Catalog Number:
86-172
List Price:
$757.69
Your Price:
$649.45
Specifications:
Volume | 100 to 1000 μL |
Number of Channels | Single-Channel |
Description | For Use With 1000µl Tips |
Qty/Unit | 1 Pipettor/Unit |
Catalog Number:
86-174
List Price:
$753.42
Your Price:
$645.79
Specifications:
Volume | 0.5 to 5 µl |
Number of Channels | Single-Channel |
Description | For Use With 5ml Tips |
Qty/Unit | 1 Pipettor/Unit |
Catalog Number:
86-177
List Price:
$2112.84
Your Price:
$1811
Specifications:
Volume | 0.5 to 10 μL |
Number of Channels | 12-Channel |
Description | For Use With 20µl Tips |
Qty/Unit | 1 Pipettor/Unit |
Catalog Number:
86-170
List Price:
$757.6
Your Price:
$649.37
Specifications:
Volume | 20 to 200 μL |
Number of Channels | Single-Channel |
Description | For Use With 200µl Tips |
Qty/Unit | 1 Pipettor/Unit |
Catalog Number:
86-168
List Price:
$757.67
Your Price:
$649.43
Specifications:
Volume | 2 to 20 μL (200 μL Tip Compatible) |
Number of Channels | Single-Channel |
Description | For Use With 200µl Tips |
Qty/Unit | 1 Pipettor/Unit |
Catalog Number:
86-165
List Price:
$757.6
Your Price:
$649.37
Specifications:
Volume | 0.1 to 2.5 μL |
Number of Channels | Single-Channel |
Description | For Use With 10µl Tips |
Qty/Unit | 1 Pipettor/Unit |
Catalog Number:
86-166
List Price:
$757.6
Your Price:
$649.37
Specifications:
Volume | 0.5 to 10 μL |
Number of Channels | Single-Channel |
Description | For Use With 20µl Tips |
Qty/Unit | 1 Pipettor/Unit |
Catalog Number:
86-169
List Price:
$757.6
Your Price:
$649.37
Specifications:
Volume | 10 to 100 μL |
Number of Channels | Single-Channel |
Description | For Use With 200µl Tips |
Qty/Unit | 1 Pipettor/Unit |
Catalog Number:
86-175
List Price:
$753.42
Your Price:
$645.79
Specifications:
Volume | 1 to 10 μL |
Number of Channels | Single-Channel |
Description | For Use With 10ml Tips |
Qty/Unit | 1 Pipettor/Unit |
Catalog Number:
86-167
List Price:
$757.6
Your Price:
$649.37
Specifications:
Volume | 2 to 20 μL |
Number of Channels | Single-Channel |
Description | For Use With 20µl Tips |
Qty/Unit | 1 Pipettor/Unit |
Catalog Number:
86-173
List Price:
$753.42
Your Price:
$645.79
Specifications:
Volume | 0.25 to 2.5 µl |
Number of Channels | Single-Channel |
Description | For Use With 2500µl Tips |
Qty/Unit | 1 Pipettor/Unit |
Catalog Number:
86-181
List Price:
$2130.73
Your Price:
$1826.34
Specifications:
Volume | 30 to 300 μL |
Number of Channels | 12-Channel |
Description | For Use With 300µl Tips |
Qty/Unit | 1 Pipettor/Unit |
Catalog Number:
86-176
List Price:
$1935.54
Your Price:
$1659.04
Specifications:
Volume | 0.5 to 10 μL |
Number of Channels | 8-Channel |
Description | For Use With 20µl Tips |
Qty/Unit | 1 Pipettor/Unit |
Catalog # | Description | Qty/Unit | Volume | Number of Channels | Price (USD) | Quantity | Add to Order | |
---|---|---|---|---|---|---|---|---|
86-165 | For Use With 10µl Tips | 1 Pipettor/Unit | 0.1 to 2.5 μL | Single-Channel | ||||
86-166 | For Use With 20µl Tips | 1 Pipettor/Unit | 0.5 to 10 μL | Single-Channel | ||||
86-167 | For Use With 20µl Tips | 1 Pipettor/Unit | 2 to 20 μL | Single-Channel | ||||
86-168 | For Use With 200µl Tips | 1 Pipettor/Unit | 2 to 20 μL (200 μL Tip Compatible) | Single-Channel | ||||
86-169 | For Use With 200µl Tips | 1 Pipettor/Unit | 10 to 100 μL | Single-Channel | ||||
86-170 | For Use With 200µl Tips | 1 Pipettor/Unit | 20 to 200 μL | Single-Channel | ||||
86-171 | For Use With 300µl Tips | 1 Pipettor/Unit | 30 to 300 μL | Single-Channel | ||||
86-172 | For Use With 1000µl Tips | 1 Pipettor/Unit | 100 to 1000 μL | Single-Channel | ||||
86-173 | For Use With 2500µl Tips | 1 Pipettor/Unit | 0.25 to 2.5 µl | Single-Channel | ||||
86-174 | For Use With 5ml Tips | 1 Pipettor/Unit | 0.5 to 5 µl | Single-Channel | ||||
86-175 | For Use With 10ml Tips | 1 Pipettor/Unit | 1 to 10 μL | Single-Channel | ||||
86-176 | For Use With 20µl Tips | 1 Pipettor/Unit | 0.5 to 10 μL | 8-Channel | ||||
86-177 | For Use With 20µl Tips | 1 Pipettor/Unit | 0.5 to 10 μL | 12-Channel | ||||
86-178 | For Use With 200µl Tips | 1 Pipettor/Unit | 10 to 100 μL | 8-Channel | ||||
86-179 | For Use With 200µl Tips | 1 Pipettor/Unit | 10 to 100 μL | 12-Channel | ||||
86-180 | For Use With 300µl Tips | 1 Pipettor/Unit | 30 to 300 μL | 8-Channel | ||||
86-181 | For Use With 300µl Tips | 1 Pipettor/Unit | 30 to 300 μL | 12-Channel |
Need help?
Call our product expert?
+1.800.789.5550
or
Contact Us
7:00am - 5:00pm PST
Monday - Friday
!